background image

5c. 10 ft. Extension Wire (for 6057 series)
6. Y-Connector
7. 4" Deck plate ( 
optional must be ordered separately)
8. 8" Deck plate ( 
optional must be ordered separately)
9. Mixing Valve ( 
optional must be ordered separately)
10. Key for vandal resistant aerator
11. 27" Extension Wire (for 6057 series)

1. Selectronic Spout Assembly
2. Mounting Kit
3. Electrical Enclosure
4. Supply Hose
5a. DC Battery (for 6055 series)
5b. AC Power Supply (for 6056 series)

All American Standard Faucets Are Water Tested At Our Factory. 
Some Residual Water May Remain In The Faucet During Shipping. 

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure 
that your installation proceeds smoothly--please read these instructions carefully before you begin.

UNPACKING

H

o

to o
rder the Select

ronic 

Pr

oduct

1. Choose 

P

o

w

er Supp

ly

2. Choose Desi

red Spout

• Single Hole Sink

• Single  Inlet

• 1 and 3 Hole Sinks

• Single Inlet

• 1 and 3 Hole Sinks

• Hot and 

C

old Inlets

Base 

Pr

oduc

t

De
ck Pla

te (optional

)

Mixing

 V

al

ve (optional)

1. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items 

after they have been removed from the carton. Some items may be packaged partially assembled to other items.

1

605P400

605P800

605XTMV

6055.102

6055.104
6055.105

PRODUCT No.s

PRODUCT No.s

6056.102

6056.104
6056.105

6057.102

6057.105

6055.163

6055.164

6055.165

6056.163

6056.164

6056.165

6057.163

6057.165

6

2

3

5a

5b

7

8

9

4

De
ck Pla

te 

Mixing

 V

al

ve

Base 

Pr

oduc

t

Cast Spout

6" GN Spout

M 9 6 8 8 0 9

 

Rev.

1

. 7

11

5c

1

10

DO NOT REMOVE PROTECTIVE

FILM FROM SENSOR EYE UNTIL

INSTALLATION IS COMPLETE.

DO NOT REMOVE PROTECTIVE

FILM FROM SENSOR EYE UNTIL

INSTALLATION IS COMPLETE.

Содержание Selectronic 6055.102

Страница 1: ...ve this manual to the customer after installation In Toronto Area only 1 905 3061093 Product No s Options Specifications How to Install Electrical Hook up Maintenance FAQ s Replacement Parts 1 2 2 3 4...

Страница 2: ...u begin UNPACKING How to order the Selectronic Product 1 Choose Power Supply 2 Choose Desired Spout Single Hole Sink Single Inlet 1 and 3 Hole Sinks Single Inlet 1 and 3 Hole Sinks Hot and Cold Inlets...

Страница 3: ...ION Use only American Standard supplied cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty Note All plumbing and electrical wiring must be i...

Страница 4: ...nting surface 1524mm 60 14 356mm 3 3 4 96mm 2 3 4 71mm 3 76mm 21 mm 2 4 3 1 1 1 20 500mm MOUNTING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing...

Страница 5: ...NNECTOR 5a through GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to EXTENSION CABLES 2 from Faucet Sensor Fig 1d 6 Replace ENCLOSURE COVER 1 Tighten cover screws firmly...

Страница 6: ...OSURE 3 Fig 2a 3 Remove SPLIT PLUG 4 from POWER SUPPLY GROMMET 5 Insert POWER CORD 7 into SPLIT PLUG 4 Insert POWER CORD CONNECTOR 6 through POWER SUPPLY GROMMET 5 Push SPLIT PLUG 4 into POWER SUPPLY...

Страница 7: ...3 3a Connect the second 27 EXTENSION CABLE 1a to the top of the Y CONNECTOR 8 5 Connect the 10 ft EXTENSION CABLE 6 to the top of the Y CONNECTOR 8 Feed the other end through the two GRAY GROMMETS 9...

Страница 8: ...e BATTERY HOLDER 4 Fig 3 3 Replace ENCLOSURE COVER Tighten cover screws firmly Fig 3 HOW TO INSTALL AND CHANGE BATTERY Fig 3 3 1 Setting the Detection Zone Distance Remove cover from ENCLOSURE Disconn...

Страница 9: ...tighten with a 7 16 socket Caution do not over tighten strainer Note It is recommended to clean strainer every 6 months 6 Open SUPPLY STOP 1 with 4mm Hex wrench 7 Replace ENCLOSURE COVER Tighten cover...

Страница 10: ...sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Q What is the normal operating pressure range A Faucet will operate with supply pressures ranging from 20 80 ps...

Страница 11: ...BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMANGE IN SENSOR WIRE REPLACE SENSOR ONLY IF ABSOLUTELY NEEDED ARE EXTERNAL SUPPLY STOPS OPEN IS INTERNAL SUPPLY STOP OPEN REPEATED DOUBL...

Страница 12: ...24162 0070A SUPPLY HOSE 044912 0070A MOUNTING NUT M964904 0070A SENSOR KIT M922887 YYY0A 1 5 GPM AERATOR M922286 YYY0A 0 35 GPM AERATOR 6055 104 6056 104 066508 YYY0A 0 5 GPM AERATOR PRODUCT NUMBERS C...

Отзывы: