FAQ'S
Q:
How will I know if battery needs to be replaced?
A:
Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q:
Why has the flow rate of the faucet reduced
significantly?
A:
Check and clean aerator and strainer.
Q:
There is no flow out of faucet when I'm in the
sensor range?
A:
Check sensor. If sensor blinks 2 times interrupted by
pause, replace battery, or call (855) 752-9259.
Q:
Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but turns
off when in sensor range?
A:
Sensor wires to solenoid are reversed.
Q:
What is the normal operating pressure range?
A:
Faucet will operate with supply pressures ranging
from 20-80 psi.
9
CAUTION
GENERAL CLEANING; Fig. 7
1.
For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2.
For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface.
Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.