background image

Fig. 2

1.

 Determine location of ENCLOSURE 

(1)

. It must be 

located with-in the 14" (356mm) by 21" (533mm) 

shaded area shown in 

Figure 2

 in order for electrical 

connections from the spout assembly to be made.

NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance 

between wall supply and ENCLOSURE (1) must be 

taken into consideration.

2.

 Remove 4 screws from COVER 

(2)

 and pull off 

COVER 

(2)

. Hold the ENCLOSURE 

(1)

 in desired 

location and mark the four mounting hole locations as 

shown. 

Fig. 2.

NOTE: For AC installation see “AC VERSION; Fig. 2.”

Make power supply connection before mounting 

ENCLOSURE (1) to wall. 

3.

 The ENCLOSURE 

(1)

 works best if secured to a wall 

stud or cross brace within the wall, using the SCREWS 

(3)

 supplied. If the ENCLOSURE 

(1)

 is to be installed on 

a tile or plaster wall the ANCHORS 

(4)

 and SCREWS 

(3)

 should be used.

4. 

For installations on drywall or tiled walls;

 use 

ANCHORS 

(4)

 and SCREWS 

(3)

 for securing 

ENCLOSURE 

(1)

 to finished wall. Drill four 1/4" dia. 

holes a minimum of 1-3/4" deep. Insert the four 

ANCHORS 

(4)

 flush with face of the finished wall.

Align the ENCLOSURE 

(1)

 and Install the MOUNTING 

SCREWS 

(3)

. Tighten to secure ENCLOSURE 

(1)

 to 

mounting surface.

  

1524mm

(60)

14"

(356mm)

3-3/4"

(96mm)

2-3/4"

(71mm)

3"

(76mm)

21"

(mm)

2

4

3

1

1

1

20"

(500mm)

MOUNTING HOLES

SUPPLIES

WASTE

ENCLOSURE

MOUNTING

HOLES

LAVATORY RIM OR

MOUNTING SURFACE

3

NOTE: If using Mixing Valve (optional) See Sheet 
#M968808 for installation instructions.

    MOUNT ENCLOSURE; Fig. 2

2

1. 

 Connect SUPPLY NUT 

(1)

  from spout assembly to 

nipple on top of ENCLOSURE 

(2)

. Tighten with 

adjustable wrench to make a water tight connection. 

Fig. 3.

NOTE; If using the optional Mixing Valve See Sheet 
#M968808 for installation instructions.

    CONNECT SPOUT HOSE TO

ENCLOSURE; Fig. 3

    CONNECT WATER SUPPLY TO 

ENCLOSURE AND WALL SUPPLY;

Fig. 4

3

Fig. 3

4

1

2

1

3

3

Fig. 4

2

1. 

Insert FIBER WASHER 

(4)

 into SUPPLY NUT 

(1)

 on 

ENCLOSURE 

(2)

.

2. 

Connect SUPPLY NUT

 (1)

 on ENCLOSURE

 (2)

 to 

FLEXIBLE SUPPLY HOSE 

(3)

. Tighten to make a 

water tight connection. Use two wrenches to tighten if 
necessary. 

Fig. 4.

3.

 Connect FLEXIBLE SUPPLY 

(3)

 directly to wall supply. 

Connection on FLEXIBLE SUPPLY 

(3)

 is 3/8" 

compression. Use adjustable wrench to tighten 

connection. Do not over tighten. 

Fig. 4a.

Note: 

FLEXIBLE SUPPLY 

(3)

 measures 20" from the 

bottom of the ENCLOSURE 

(1)

 base. If additional 

supply length is required, installer must purchase parts 

separately.

Important: 

If FLEXIBLE SUPPLY 

(3)

 is too long, loop to 

avoid kinking.

COLD WATER OR

TEMPERED

WALL SUPPLY

Fig. 4a

4

M 9 6 8 8 0 9

 

Rev. 1. 7

Содержание Selectronic 6055.102

Страница 1: ...ve this manual to the customer after installation In Toronto Area only 1 905 3061093 Product No s Options Specifications How to Install Electrical Hook up Maintenance FAQ s Replacement Parts 1 2 2 3 4...

Страница 2: ...u begin UNPACKING How to order the Selectronic Product 1 Choose Power Supply 2 Choose Desired Spout Single Hole Sink Single Inlet 1 and 3 Hole Sinks Single Inlet 1 and 3 Hole Sinks Hot and Cold Inlets...

Страница 3: ...ION Use only American Standard supplied cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty Note All plumbing and electrical wiring must be i...

Страница 4: ...nting surface 1524mm 60 14 356mm 3 3 4 96mm 2 3 4 71mm 3 76mm 21 mm 2 4 3 1 1 1 20 500mm MOUNTING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing...

Страница 5: ...NNECTOR 5a through GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to EXTENSION CABLES 2 from Faucet Sensor Fig 1d 6 Replace ENCLOSURE COVER 1 Tighten cover screws firmly...

Страница 6: ...OSURE 3 Fig 2a 3 Remove SPLIT PLUG 4 from POWER SUPPLY GROMMET 5 Insert POWER CORD 7 into SPLIT PLUG 4 Insert POWER CORD CONNECTOR 6 through POWER SUPPLY GROMMET 5 Push SPLIT PLUG 4 into POWER SUPPLY...

Страница 7: ...3 3a Connect the second 27 EXTENSION CABLE 1a to the top of the Y CONNECTOR 8 5 Connect the 10 ft EXTENSION CABLE 6 to the top of the Y CONNECTOR 8 Feed the other end through the two GRAY GROMMETS 9...

Страница 8: ...e BATTERY HOLDER 4 Fig 3 3 Replace ENCLOSURE COVER Tighten cover screws firmly Fig 3 HOW TO INSTALL AND CHANGE BATTERY Fig 3 3 1 Setting the Detection Zone Distance Remove cover from ENCLOSURE Disconn...

Страница 9: ...tighten with a 7 16 socket Caution do not over tighten strainer Note It is recommended to clean strainer every 6 months 6 Open SUPPLY STOP 1 with 4mm Hex wrench 7 Replace ENCLOSURE COVER Tighten cover...

Страница 10: ...sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Q What is the normal operating pressure range A Faucet will operate with supply pressures ranging from 20 80 ps...

Страница 11: ...BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMANGE IN SENSOR WIRE REPLACE SENSOR ONLY IF ABSOLUTELY NEEDED ARE EXTERNAL SUPPLY STOPS OPEN IS INTERNAL SUPPLY STOP OPEN REPEATED DOUBL...

Страница 12: ...24162 0070A SUPPLY HOSE 044912 0070A MOUNTING NUT M964904 0070A SENSOR KIT M922887 YYY0A 1 5 GPM AERATOR M922286 YYY0A 0 35 GPM AERATOR 6055 104 6056 104 066508 YYY0A 0 5 GPM AERATOR PRODUCT NUMBERS C...

Отзывы: