18-CE03D1-1F-EN
95
1.
Remove the three inducer mounting screws.
2.
Rotate inducer counterclockwise so that the inducer outlet aligns
with the exhaust vent outlet.
3.
Reinsert and tighten screws to 30 in.-lbs. Do not overtighten.
1.
Remove the pressure switch bracket assembly.
2.
Remove the screw that holds PS2, rotate 90 degrees
counterclockwise, and reattach.
3.
Reattach the pressure switch bracket assembly.
Note:
The illustration shows PS2 in its final position after being
rotated.