background image

FAILURE TO PROVIDE AN EXPANSION TANK ON THE COLD WATER LINE ON A CLOSED SYSTEM WILL VOID THE WARRANTY 
ON THE WATER HEATER.

FOR YOUR SAFETY

Do not use or store gasoline or any other flammable vapors, liquids, or materials in vicinity of this or any other appliance.

FOR YOUR SAFETY - WHAT TO DO IF YOU SMELL GAS

. Do not try to light any appliance.
. Do not touch any electrical switch; do not use any phone in your building.
. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier´s instructions.
. If you cannot reach your gas supplier, call the fire department.

Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. 
For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

THIS WATER HEATER MUST BE PROPERLY AND REGULARLY MAINTAINED.

FAILURE TO DO SO WILL VOID THE WARRANTY.

Please complete the following information at the time of installation. This should be retained and presented along with the warranty in case a claim 
is necessary.

MODEL NUMBER:                                                                    TYPE:
SERIAL NUMBER:
INSTALLATION ADDRESS:
 

THIS WATER HEATER HAS BEEN INSTALLED IN ACCORDANCE WITH THESE INSTALLATION
INSTRUCTIONS AND LOCAL CODE REQUIREMENTS ON

INSTALLER:

DATE

WARNING

WARNING

1

2

CONSUMER RESPONSIBILITIES

WARRANTY LIMITATIONS

THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE RESPONSIBLE FOR TANK FAILURES OR WATER HEATER FAILURES RESULTING FROM ANY OF 
THE FOLLOWING CONDITIONS AND MAY AT IT’S DISCRETIONS VOID THE WATER HEATER WARRANTY WHEN THESE CONDITIONS RESULT IN 
PREMATURE FAILURES OF THE TANK OR COMPONENTS

1. INSTALLATIONS NOT COMPLYING WITH ALL LOCAL CODES.
2. FAILURES DUE TO UNDERSIZING OF THE WATER HEATER AND SUBSEQUENT EXCESSIVE BURNER FIRING.
3. BAD WATER CONDITIONS SUCH AS WELL WATER WITH EXCESSIVE MINERAL DEPOSITS. IT IS THE RESPONSABILITY OF THE INSTALLER TO TAKE WHAT EVER STEPS 
ARE REQUIRED INCLUDING THE INSTALLATION OF WATER HEATER SOFTENERS, TO PREVENT EXCESSIVE LIME BUILD UP AND SUBSEQUENT METAL FATIGUE DUE TO 
OVER HEATING OF THE TANK BOTTOM AND TO USE THE HAND HOLE CLEANOUT  PROVIDED IN THIS WATER HEATER TO KEEP LIME DEPOSITS IN THE TANK BOTTOM 
EXCEEDING FROM 2” HEIGHT.
4. INSTALLATION OF MULTIPLE WATER HEATERS IN SEQUENCE RATHER THAN PARALLEL RESULTING IN EXCESS FIRING AND/OR  EXCESSIVE CONDENSATIONS ON 
FIRST HEATER IN SERIES OR OUT OF BALANCE PILOT OUTAGES AND PREMATURE FAILURE OF BURNER COMPONENT PARTS WILL OCCUR.
5. FAILURE TO PROVIDE ADEQUATE COMBUSTION AIR AND A CONTAMINATED AIR OUTLET OR TO ADEQUATE PROPER VENTING RESULTING IN NEGATIVE AIR 
PRESSURE DUE TO IMPROPER LOCATION OR LACK OF COMBUSTION SHOWN ON OWNERS OPERATION MANUAL AND THE INSTALLATION IN COMPLIANCE WITH 
UNIFORM PLUMB CODE.
6. FAILURE TO INSTALL HEATERS TO MANUFACTURE AND BUILDING SAFETY STANDARDS WILL CAUSE PREMATURE FAILURE OF COMPONENT PARTS, HAZARDOUS 
CONDITIONS AND FAILURE OF THE HEATER OR COMPONENTS CAUSED BY CHEMICALS OR SOLVENTS BEING STORED IN THE INMEDIATE VICINITY OF THE WATER 
HEATER. 
7. FAILURE TO PROVIDE A PROPERLY SIZED EXPANSION TANK ON THE COLD WATER LINE ON A CLOSED SYSTEM.
8. FAILURE ADEQUATE GAS SUPPLY AND PROPER PRESSURE AS OUTLINED ON OWNERS OPERATION MANUAL INSTALLED IN COMPLIANCE WITH UNIFORM PLUMBING 
CODE.
9. FAILURE TO INSTALL TEMPERATURE PRESSURE RELIEF VALVE DRAIN AS PER OWNERS OPERATION MANUAL  AND IN COMPLIANCE WITH UNIFORM PLUMBING CODE.
10. FAILURE TO SET UP THE ELECTRICAL INSTALLATION IN COMPLIANCE TO OPERATION MANUAL AND TO NATIONAL ELECTRIC CODE. 

THIS MANUAL HAS BEEN PREPARED TO ACQUAINT YOU WITH THE INSTALLATION, OPERATION AND 

MAINTENANCE OF YOUR GAS WATER HEATER AND TO PROVIDE IMPORTANT SAFETY INFORMATION.

WE URGE YOU TO READ ALL INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR 

OPERATION OF YOUR WATER HEATER. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.

The manufacturer of this water heater will not be liable for any damages caused by failure to comply with the installation and operating instructions 
outlined on the following pages. These instructions are a guide for the correct installation of your water heater. lf you lack the necessary skills 
required or have difficulty following the directions, you should not proceed but get help from a qualified person for that part of the installation you 
do not understand. Your gas-fired water heater is design-certified by ETL. The installation should conform with the local code or the authority 
having jurisdiction, or in the absence of such, the National Gas Code. ANSI Z223.1 NFPA 54. A copy of the Code can be purchased from American 
Gas Association Order Processing, 400 N. Capital St. N.W. Washington D.C. 20001 e-mail ordering: www.aga.org Fax ordering: 866-8 I6-9444. 
A rating plate identifying your water heater will be found next to the gas control valve (thermostat).

The water utility supply meter may contain a check valve, back flow preventer or water pressure reducing valve. This will create a closed water 
system. During the heating cycle of the water heater, the water expands creating a pressure build up in the water system. A temperature and 
pressure relief valve must be installed on the water heater (150 PSI maximum pressure setting. See Temperature and Pressure Relief Valve). 

If the water supply system contains a check valve, back flow preventer, or water pressure reducing valve you will have closed 

water system and the pressure will build up during the water heating cycle. The temperature and pressure relief valve on the 

water heater will leak during the water heating cycle resulting in loss of energy. To prevent the build up of lime in the T&P valve 

and damage to the water heater by pressure surges you must install an expansion tank on the cold water supply line. The thermal 

expansion tank should have a minimum capacity of 4.5 U.S. gallons. It requires both T&P valves and expansion tanks for closed 

system.
Multiple water heating system and/or a system with additional storage tank must be sized by thermal expansion tank 

manufacturer.

WARNING CLOSED WATER SYSTEMS

PRESSURE BUILD-UP IN CLOSED WATER SYSTEMS

Содержание PLC 100-76

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga...

Страница 2: ...OUR RECEIPT TO SHOW TO THE SERVICE PERSON IF SERVICE IS REQUIRED OPERATING INSTALLATION AND SERVICE MANUAL STORAGE TYPE GAS WATER HEATER WITH FLUE DAMPER WARNING If the information in these instructio...

Страница 3: ...ts Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperatu...

Страница 4: ...d replace anode Install in location with drainage Fill tank with water before operation Be alert for thermal expansion Refer to instrucion manual for installation and service Improper installation and...

Страница 5: ...EATER WITH WATER INSTALLATION CHECK LIST NATURAL GAS MODELS L P PROPANE BOTTLED GAS MODELS OUT OF FUEL EXPOSURE TO WATER INSTRUCTIONS FOR CLEANING TANK TO RETURN WATER HEATER TO OPERATION VACATION COM...

Страница 6: ...E THIS MANUAL HAS BEEN PREPARED TO ACQUAINT YOU WITH THE INSTALLATION OPERATION AND MAINTENANCE OF YOUR GAS WATER HEATER AND TO PROVIDE IMPORTANT SAFETY INFORMATION WE URGE YOU TO READ ALL INSTRUCTION...

Страница 7: ...ion adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the g...

Страница 8: ...ude Contact the company listed on the rating label when ordering high altitude constructed water heaters For any questions not covered in this booklet contact your dealer or write to us at the address...

Страница 9: ...rents NOTE HEATER SHALL BE LOCATED OR PROTECTED SO IT IS NOT SUBJECT TO PHYSICAL DAMAGE BY MOVING VEHICLES OR AREA FLOODING Typical Installation in Residential Garages Illustration copyright by the Am...

Страница 10: ...the water heater and the combustion air inlet must be in the same atmospheric pressure zone Large exhaust fans in kitchens or other locations can lower the air pressure inside an enclosure and interfe...

Страница 11: ...r to check the installation for venting and for spillage all around the draft hood relief opening after five minutes of operation the method to check for flue products spillage should utilize a flame...

Страница 12: ...e a good grade of pipe joint compound Be familiar with the location of the shut off valve in the cold water line feeding the water heater See Figure 5 If a valve is not present one shall be installed...

Страница 13: ...ft 91 cm above if within 10ft 3m Horizontally E Clearance to unventilated 12 in L Above paved sidewalk or paved driveway located on public property 7 ft 2 13 m for mechanical draft systems category I...

Страница 14: ...H SUITABLE DRAIN OPEN DRAIN HAND HOLE CLEAN OUT T P RELIEFVALVE COLDWATER INLET SHUT OFFVALVE EXPANSIONTANK STORAGETANK CHECK VALVE DRAINVALVE Use an ExpansionTank in a closed water system ColdWater S...

Страница 15: ...ff valve Shut off valve Shut off valve Shut off valve Bleed valve System return Union Union Expansion tank Water supply Back flow preventers PUMP SINGLE COMMERCIAL GAS MODEL TOP CONNECTIONS WITH RETUR...

Страница 16: ...er commercial or household products When urned vapors from these products form highly corrosive acid compounds These products should not be stored or used near the water heater or air inlet Combustion...

Страница 17: ...ommunicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 BTU per hour of total input rating of all equipment in the enclosure Figure...

Страница 18: ...equipment in the enclosure Illustration for Figures 6 9 copyright by the American Gas Association Used by permission of the copyright holder MECHANICAL EXHAUSTING AND FIREPLACES the operation of air...

Страница 19: ...ground level will serve as pockets for accumulation of leaking gas Before lighting sniff at floor level IF YOU SMELL GAS follow applicable instructions on Front Cover or Page 21 DO NOT OPERATE APPLIAN...

Страница 20: ...e cigar or pipe Do not smoke If hydrogen is present there will probably be an unusual sound such as air escaping through the faucet as the water begins to flow Remember no smoking or open flame near t...

Страница 21: ...the water flow may cause property damage The discharge line 1 Must not be smaller than the pipe size of the relief valve 2 Must not be plugged or blocked 3 Must be of material capable of withstanding...

Страница 22: ...ING THE HEATER WITH WATER 1 Close the heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of heater 2 Open the cold water supply valve to the heater 3...

Страница 23: ...ure 5 Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas leaks The installer to visually determine that the main burner flames are bu...

Страница 24: ...t FLOOR LEVEL IF YOU SMELL GAS FOLLOW THESE RULES 1 Open windows 2 Get all people out of the building 3 DO NOT light matches Extinguish any open flame 4 DO NOT touch electrical switches on or off 5 SH...

Страница 25: ...dge 7 After tank has cooled remove loose scale and lime deposits from inside tank being careful not to break glass lining TO RETURN WATER HEATER TO OPERATION I Replace hand hole clean out gasket 2 Re...

Страница 26: ...140 F a mixing valve or other means should be installed in the domestic potable hot water supply to limit the RISK OF SCALD DAMAGE SOME JURISDICTIONS may require a backflow preventer in the incoming c...

Страница 27: ...D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control...

Страница 28: ...IMIT The thermostat on this water heater is equipped with a high temperature limit switch ECO The ECO will shut off the gas supply to the burner and pilot in the event the water temperature exceeds 19...

Страница 29: ...urner and pilot flames Observation of the gas flame should show the burner flame to be a soft blue with the suggestion of slight yellow tips It is to be noted that the flame of a light color may not b...

Страница 30: ...d if being shut down during freezing temperatures Also periodic draining and cleaning of sediment from the tank may be necessary See Page 22 I Turn gas valve knob clockwise to the OFF position 2 Close...

Страница 31: ...eplace with correct orifice Clear the area near the heater Check with utility Clean check for source of trouble correct Clean check for source of trouble correct Provide ventilation by use of louvers...

Страница 32: ...ice too small Thermostat set too low Sediment or lime in tank Heater too small for job Wasted hot water Clear the area near the heater Check with utility Replace with correct orifice Turn temperature...

Страница 33: ...number from the following list part description voltage and wattage when applicable It is imperative that replacement of main burner orifices pilot burner and gas valve be ordered for the gas type Nat...

Страница 34: ...29 REPLACEMENT PARTS ILLUSTRATION STANDARD MODEL SHOWN Figure 17 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 35: ...NG POTABLE WATER HEATING SYSTEM WATER POTABLE HEATING AND SPACE HEATING NON SCALD TEMPERING VALVE SUGGESTED PIPING ARRANGEMENT FOR TOP CONNECTIONS TEMPERED POTABLE WATER COLD WATER INLET RETURN FROM H...

Страница 36: ...REV APRIL 2021 ITEM 420011141900 561 New York Drive Pomona California 91768 Toll Free 800 900 9063 Fax 909 392 7302...

Отзывы: