WARNINGS

WARRANTY LIMITATIONS, 
CONSUMER RESPONSABILITIES, PRESSUHRE BUILD-UP IN CLOSED WATER SYSTEMS,

GENERAL, INSTALLATION

DRAFTHOOD LOCATION & FLUE DAMPER INSTALLATION, VENTING

WATER CONNECTIONS, GAS PIPING

TYPICAL INSTALLATION

SINGLE COMMERCIAL GAS MODEL
TOP CONNECTIONS WITH RETURN CIRCULATION

AIR SUPPLY, ALL AIR FROM INSIDE THE BUILDING

ALL AIR FROM OUTDOORS

DISCHARGE OF PURGED GASES, VENTING

INSTALLATION SAFETY WARNING L.P. UNITS, ANODES, MULTIPLE HEATER INSTALLATION

INSTALLATION (USING TOP CONNECT ONLY) 

TEMPERATURE AND PRESSURE RELIEF VALVE

FILLING HEATER WITH WATER

INSTALLATION CHECK LIST

NATURAL GAS MODELS, 
L.P. (PROPANE, BOTTLED) GAS MODELS, OUT OF FUEL EXPOSURE TO WATER

INSTRUCTIONS FOR CLEANING  TANK, TO RETURN WATER HEATER TO OPERATION, VACATION

COMBINATION SPACE HEATING /POTABLE WATER 
HEATING SYSTEM, VENTING SYSTEM INSPECTION, CONDENSATION

FOR YOUR SAFETY READ BEFORE OPERATING, OPERATING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE, HI-TEMPERATURE LIMIT,
WATER TEMPERATURE REGULATION, TEMPERATURE CONTROL

GAS PRESSURE, EMERGENCY SHUTDOWN INSTRUCTIONS, TAMPERING, MAINTENANCE

PILOT AND MAIN BURNER, WATER HEATER SOUNDS, DRAINING

COMMON ISSUES

REPLACEMENT PARTS LIST

REPLACEMENT PARTS ILLUSTRATION

COMBINATION SPACE HEATING / POTABLE WATER HEATING SYSTEM

A

1

3

6

7

8

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

C

D

WARNING

Read and understand instruction manual and safety 
messages before installing, operating, or servicing 
this water heater.

Failure to follow instructions and safety messages 
could result in death or serious injury.

Instruction manual must remain with water heater.

DANGER

Water temperature over 125°f (52°c) can cause 
severe burns instantly resulting in severe injury or 
death.

Children, the elderly, and the physically or mentally 
disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting valves are available.

Read instruction manual for safe temperature 
setting.

WARNING

For continued protection against risk of fire:

. Do not install water heater on carpeted floor.
. Do not operate water heater if flood damaged.

Fire Hazard

WARNING

. Overheated water can cause water tank          
  explosion.

. Properly sized temperature and pressure relief        
  valve must be installed in opening provided.

Explosion Hazard

CAUTION

. Do not operate water heater if flood damaged.
. Inspect and replace anode.
. Install in location with drainage.
. Fill tank with water before operation.
. Be alert for thermal expansion.

Refer to instrucion manual for installation and service.

Improper installation and use may result in property damage.

WARNING

. Install vent system in accordance with codes and 
regulations.

. Do not operate water heater if flood damaged.

. High altitude orifice must be installed for     
  operation above 7,700 feet (2,347m).

. Do not operate if soot buildup.

. Do not place chemical vapor emitting products  
  near water heater.

. Gas and carbon monoxide detectors are available.

Breathing carbon monoxide can cause brain damage or death. 

Always read and understand the instruction manual

Breathing Hazard - Carbon Monoxide Gas

WARNING

. Do not store or use gasoline or other flammable vapors or liquids in the      
  vicinity of this or any other appliance.

. Avoid all ignition sources if you smell LP gas.

. Do not expose water heater control to excessive gas pressure.

. Use only gas shown on rating plate.

. Mantain required clearances to combustibles.

. Keep ignition sources away from faucets after extended period of non-use.

Read instruction manual before

installing, using, or servicing 

water heater.

Fire or Explosion Hazard

Содержание PLC 100-76

Страница 1: ...e Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga...

Страница 2: ...OUR RECEIPT TO SHOW TO THE SERVICE PERSON IF SERVICE IS REQUIRED OPERATING INSTALLATION AND SERVICE MANUAL STORAGE TYPE GAS WATER HEATER WITH FLUE DAMPER WARNING If the information in these instructio...

Страница 3: ...ts Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperatu...

Страница 4: ...d replace anode Install in location with drainage Fill tank with water before operation Be alert for thermal expansion Refer to instrucion manual for installation and service Improper installation and...

Страница 5: ...EATER WITH WATER INSTALLATION CHECK LIST NATURAL GAS MODELS L P PROPANE BOTTLED GAS MODELS OUT OF FUEL EXPOSURE TO WATER INSTRUCTIONS FOR CLEANING TANK TO RETURN WATER HEATER TO OPERATION VACATION COM...

Страница 6: ...E THIS MANUAL HAS BEEN PREPARED TO ACQUAINT YOU WITH THE INSTALLATION OPERATION AND MAINTENANCE OF YOUR GAS WATER HEATER AND TO PROVIDE IMPORTANT SAFETY INFORMATION WE URGE YOU TO READ ALL INSTRUCTION...

Страница 7: ...ion adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the g...

Страница 8: ...ude Contact the company listed on the rating label when ordering high altitude constructed water heaters For any questions not covered in this booklet contact your dealer or write to us at the address...

Страница 9: ...rents NOTE HEATER SHALL BE LOCATED OR PROTECTED SO IT IS NOT SUBJECT TO PHYSICAL DAMAGE BY MOVING VEHICLES OR AREA FLOODING Typical Installation in Residential Garages Illustration copyright by the Am...

Страница 10: ...the water heater and the combustion air inlet must be in the same atmospheric pressure zone Large exhaust fans in kitchens or other locations can lower the air pressure inside an enclosure and interfe...

Страница 11: ...r to check the installation for venting and for spillage all around the draft hood relief opening after five minutes of operation the method to check for flue products spillage should utilize a flame...

Страница 12: ...e a good grade of pipe joint compound Be familiar with the location of the shut off valve in the cold water line feeding the water heater See Figure 5 If a valve is not present one shall be installed...

Страница 13: ...ft 91 cm above if within 10ft 3m Horizontally E Clearance to unventilated 12 in L Above paved sidewalk or paved driveway located on public property 7 ft 2 13 m for mechanical draft systems category I...

Страница 14: ...H SUITABLE DRAIN OPEN DRAIN HAND HOLE CLEAN OUT T P RELIEFVALVE COLDWATER INLET SHUT OFFVALVE EXPANSIONTANK STORAGETANK CHECK VALVE DRAINVALVE Use an ExpansionTank in a closed water system ColdWater S...

Страница 15: ...ff valve Shut off valve Shut off valve Shut off valve Bleed valve System return Union Union Expansion tank Water supply Back flow preventers PUMP SINGLE COMMERCIAL GAS MODEL TOP CONNECTIONS WITH RETUR...

Страница 16: ...er commercial or household products When urned vapors from these products form highly corrosive acid compounds These products should not be stored or used near the water heater or air inlet Combustion...

Страница 17: ...ommunicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 BTU per hour of total input rating of all equipment in the enclosure Figure...

Страница 18: ...equipment in the enclosure Illustration for Figures 6 9 copyright by the American Gas Association Used by permission of the copyright holder MECHANICAL EXHAUSTING AND FIREPLACES the operation of air...

Страница 19: ...ground level will serve as pockets for accumulation of leaking gas Before lighting sniff at floor level IF YOU SMELL GAS follow applicable instructions on Front Cover or Page 21 DO NOT OPERATE APPLIAN...

Страница 20: ...e cigar or pipe Do not smoke If hydrogen is present there will probably be an unusual sound such as air escaping through the faucet as the water begins to flow Remember no smoking or open flame near t...

Страница 21: ...the water flow may cause property damage The discharge line 1 Must not be smaller than the pipe size of the relief valve 2 Must not be plugged or blocked 3 Must be of material capable of withstanding...

Страница 22: ...ING THE HEATER WITH WATER 1 Close the heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of heater 2 Open the cold water supply valve to the heater 3...

Страница 23: ...ure 5 Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas leaks The installer to visually determine that the main burner flames are bu...

Страница 24: ...t FLOOR LEVEL IF YOU SMELL GAS FOLLOW THESE RULES 1 Open windows 2 Get all people out of the building 3 DO NOT light matches Extinguish any open flame 4 DO NOT touch electrical switches on or off 5 SH...

Страница 25: ...dge 7 After tank has cooled remove loose scale and lime deposits from inside tank being careful not to break glass lining TO RETURN WATER HEATER TO OPERATION I Replace hand hole clean out gasket 2 Re...

Страница 26: ...140 F a mixing valve or other means should be installed in the domestic potable hot water supply to limit the RISK OF SCALD DAMAGE SOME JURISDICTIONS may require a backflow preventer in the incoming c...

Страница 27: ...D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control...

Страница 28: ...IMIT The thermostat on this water heater is equipped with a high temperature limit switch ECO The ECO will shut off the gas supply to the burner and pilot in the event the water temperature exceeds 19...

Страница 29: ...urner and pilot flames Observation of the gas flame should show the burner flame to be a soft blue with the suggestion of slight yellow tips It is to be noted that the flame of a light color may not b...

Страница 30: ...d if being shut down during freezing temperatures Also periodic draining and cleaning of sediment from the tank may be necessary See Page 22 I Turn gas valve knob clockwise to the OFF position 2 Close...

Страница 31: ...eplace with correct orifice Clear the area near the heater Check with utility Clean check for source of trouble correct Clean check for source of trouble correct Provide ventilation by use of louvers...

Страница 32: ...ice too small Thermostat set too low Sediment or lime in tank Heater too small for job Wasted hot water Clear the area near the heater Check with utility Replace with correct orifice Turn temperature...

Страница 33: ...number from the following list part description voltage and wattage when applicable It is imperative that replacement of main burner orifices pilot burner and gas valve be ordered for the gas type Nat...

Страница 34: ...29 REPLACEMENT PARTS ILLUSTRATION STANDARD MODEL SHOWN Figure 17 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 35: ...NG POTABLE WATER HEATING SYSTEM WATER POTABLE HEATING AND SPACE HEATING NON SCALD TEMPERING VALVE SUGGESTED PIPING ARRANGEMENT FOR TOP CONNECTIONS TEMPERED POTABLE WATER COLD WATER INLET RETURN FROM H...

Страница 36: ...REV APRIL 2021 ITEM 420011141900 561 New York Drive Pomona California 91768 Toll Free 800 900 9063 Fax 909 392 7302...