Hot water
Shut off valve
Shut off valve
Shut off valve
Shut off valve
Bleed valve
System return
Union
Union
Expansion tank
Water supply
Back flow
preventers
PUMP
SINGLE COMMERCIAL GAS MODEL
TOP CONNECTIONS WITH RETURN CIRCULATION
10
9
TYPICAL INSTALLATION
Min. 1/4 in. rise
per linear feet
VENT CONNECTOR
DRAFTHOOD
HOT WATER OUTLET
RATING PLATE
Manual Shut-Off Valve
Ground Joint Union
Minimum 4”
6 in Minimum
Drip Leg & Cap
(Sediment Trap)
THERMOSTAT
DRIP PAN WITH SUITABLE DRAIN
OPEN DRAIN
HAND HOLE
CLEAN OUT
T&P RELIEF VALVE
COLD WATER INLET
SHUT OFF VALVE
EXPANSION TANK
STORAGE TANK
CHECK
VALVE
DRAIN VALVE
Use an Expansion Tank in
a closed water system
Cold Water Supply
Return Line
from service
(when used)
Hot Water Service
Discharge to an OPEN DRAIN. DO NOT
thread, cap or plug the end discharge line.
Discharge line should be at least ¾” ID &
pitched for proper drainage to open drain.
Figure 5