d.
For maximum efficiency
, the horizontal drip
tray should be removed. See Figures 10, 11 and
12. Tray removal requires that the coil be re-
moved by sliding the coil out on the coil channel
supports. For the TEE3D40-65 units, there is a
coil support tab at the top of the coil connected to
the case that must be removed first. Remove 1
inch insulation strip covering the lip of the drip
tray. The tray is detached by removing the two
screws at the drain pan. Remove the two screws
holding the two brackets at the top of the coil.
Remove drip tray by gently breaking the seal be-
tween the drip tray and drain pan.
e. Remove the factory installed baffle assembly
from the apex of the coil by using a 5/16"
nutdriver to remove the screws. Replace this
baffle with the factory supplied narrow coil baffle
using the screws removed previously. See Figure
15. Reinstall coil assembly.
▲
CAUTION
!
When installing the narrow coil baffle, make sure to
align the baffle up with the holes so NOT to puncture
the coil tubing.
f. Position unit on Pedestal or other suitable foun-
dation. If Pedestal is not used, a frame strong
enough to support the total weight must be pro-
vided. Provide a minimum height of 14 inches for
proper unrestricted airflow. In open return ap-
plications, installation requires a
BAYPLNM
or
TASB
stand.
g. If a return air duct is connected to the air han-
dler, it must be the same dimensions as shown in
the outline drawing on page 20.
h.
On units with sheetmetal returns: Return
plenum must be flanged. Sheetmetal screws
must be 1/2" in length or shorter. Self-tap-
ping screws are supplied with unit in ac-
cessory pack.
See Figure 17.
i.
No sheetmetal screws may be used to at-
tach return duct work on the side of the
unit.
j. Pedestal and unit should be isolated from the
foundation using a suitable isolating material.
k.
Openings where field wiring enters the
cabinet must be completely sealed.
Location
of power entry is shown on the Outline Drawing.
Use 2.5" clear stickers provided to seal all unused
electrical knockouts. See Figure 16.
l. After ductwork connections are made, seal air-
tight and per Local codes.
m. Install FIELD CHARGER as shown in Figure 18
(Upflow). Ionizing pins must face downward (into
the return air stream) and electrical contacts
must be on the left side of the unit.
n. Reinstall FIELD CHARGER retainer bracket.
o. Install COLLECTION CELL as shown in Figure
18 (Upflow) so that electrical contacts and actua-
tor tab are on the left side of the unit.
p. Install filter panel with thumbscrews.
DOWNFLOW
a. Before installing unit, remove thumbscrews to
the filter panel. Carefully remove the COLLEC-
TION CELL by grasping the leading edge of the
frame. See Figure 6. Set aside in a safe place un-
til the unit is set in place and ready to start up.
b. Use a 5/16" nutdriver to remove the screw in the
FIELD CHARGER retainer and take out both.
Slightly lift the FIELD CHARGER and carefully
remove. Set aside in a safe place until the unit is
set in place and ready to start up. See Figures 7
and 8.
c. Position unit to remove the bottom protector
plate by laying the unit on its back. Use a flat
blade screwdriver between the protector plate
and the unit to pry apart. See Figure 9. Gently
pull the plate towards the front of the unit to re-
move.
d.
For maximum efficiency
, the horizontal drip
tray should be removed. See Figures 10, 11 and
12. Tray removal requires that the coil be re-
moved by sliding the coil out on the coil channel
supports. For the TEE3D40-65 units, there is a
coil support tab at the top of the coil connected to
the case that must be removed first. Remove 1
inch insulation strip covering the lip of the drip
tray. The tray is detached by removing the two
screws at the drain pan and the two screws hold-
ing the two brackets at the top of the coil. Re-
move drip tray by gently breaking the seal be-
tween the drip tray and drain pan.
e. Remove the factory installed baffle assembly
from the apex of the coil by using a 5/16"
nutdriver to remove the screw. Replace this
baffle with the factory supplied narrow coil baffle
using the screws removed previously. See Figure
15.
▲
CAUTION
!
When installing the narrow coil baffle, make sure to
align the baffle up with the holes so NOT to puncture
the coil tubing.
NOTE: Installation of the downflow baffle kit included
with unit is required on downflow applications. See
Figure 14.
f. Remove front shield by removing screws on right
side. Make sure to reinstall front shield after
baffle changes. See Figure 14.
g. Detach the coil from the drain pan by removing 4
screws as shown in Figure 14.