18-GE10D1-4
3
Installer’s Guide
11. If the unit is installed without a return air duct, ap-
plicable local codes may limit this air handler to in-
stallation only in a single story residence & within
conditioned space.
12. If the outdoor unit is to be installed later, or by oth-
ers, then installation of the air handler must be
made to allow access for refrigerant lines, or attach
refrigerant lines to air handler when installing.
13. Make sure there are provisions for installing con-
densate drain lines.
14. If side, front or rear return is required, air handler
must be elevated or placed on a plenum
(TAYPLNM100 or 101). Connecting return duct di-
rectly to the side, front or rear of the cabinet is not
approved.
1
3
2
4
Figure 2 Components of the Integrated Whole House Air Cleaner
1) FIELD CHARGER
- Charges the contaminants
2) COLLECTION CELL
- removes and collects very small
impurities from the air.
3) Power Supply
- the solid state power supply converts the
24 Volt AC to the high-voltage, direct current required to
power the FIELD CHARGER and COLLECTION CELL.
4) Safety Switch
- cuts off all power to the FIELD CHARGER
and COLLECTION CELL when disengaged.
Check carefully for any shipping damage. This must be
reported to and claims made against the transporta-
tion company immediately. Check to be sure all major
components are in the unit. Any missing parts should
be reported to your supplier at once, and replaced with
authorized parts only.
From Dwg. 21B140413
4"
6"
17"
1"
3/8"
1/4" HOLES (4)
ACCESSORY BAY99X123
IF AIRHANDLER IS USED
WITHOUT
A FACTORY FURNISHED
SUPPLEMENTARY HEATER, A PLATE IS REQUIRED TO COVER
THE OPEN HOLE IN THE AIR FLOW SYSTEM
Figure 3
15. Route refrigerant & condensate drain lines away
from air handler so they do not interfere with ac-
cess panels and COLLECTION CELL removal.
16. When external accessories are used, the additional
height and width requirements must be considered
in the overall space needed.
17. These units are not approved for outdoor installa-
tion.
18. These units are approved for draw-through application
only.
19. DO NOT use silicon based sealant. This causes a
coating on the FIELD CHARGER pins that will de-
crease the efficiency of the air cleaner.
NOTE: No atomizing style humidifier is allowed in the
return plenum with the use of this unit.
20.
Flow-through Bypass Humidifiers
Excessive bypass air may cause water blow-off,
which will adversely affect system operation and air
cleaner performance. To verify bypass airflow, fol-
low the Bypass Humidifier Pre-Installation Check-
out and Set-Up Procedures available through your
local distributor. Ask for publication number 18-
CH37D1-1.