background image

Document in original language | 137667 · A001

Topvex SC03-11
Compact Air Handling Unit

Installation instructions

GB

Содержание Topvex SC03-11

Страница 1: ...Document in original language 137667 A001 Topvex SC03 11 Compact Air Handling Unit Installation instructions GB ...

Страница 2: ... Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications ...

Страница 3: ... storage 6 4 Installation 7 4 1 Unpacking 7 4 2 Where how to install 7 4 3 Condensation drain 9 4 4 Installing the unit 10 4 4 1 Installation procedure 11 4 5 Supply air sensor 12 4 6 Connections 13 4 6 1 Ducting 13 4 6 2 Condensation and heat insulation 14 4 6 3 Silencers 14 4 6 4 Electric connections components 15 4 6 5 External connections 16 4 6 6 BMS Connection 16 4 7 Installing the control p...

Страница 4: ......

Страница 5: ...100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements EN 60335 2 40 Sa...

Страница 6: ...enance shall not be made by children without supervision 3 Product information 3 1 General This installation manual concerns air handling unit type Topvex SC03 11 manufactured by Systemair Sverige AB Top vex SC03 11 include the following model options Model SC03 SC04 SC06 SC08 SC11 Heating coil EL Electric HW Water coil or None Right or left models R Right L Left The side where the supply air is l...

Страница 7: ... D E E O G I L K 1 2 P Fig 1 Dimensions mm SC03 SC04 Drawn as left hand unit Model A B C D E F G H P SC03 1597 1531 730 790 371 365 231 118 792 SC04 1941 1531 730 790 371 365 181 118 965 Model I J K L M N O Weight kg SC03 280 58 1463 597 61 100 315 280 SC04 380 58 1814 597 61 100 400 330 male 137667 A001 ...

Страница 8: ...t Topvex SC06 T T U 1 2 Fig 2 Dimensions mm SC06 Drawn as left hand unit Model A B C D E F G H I J K L SC06 2175 1622 895 619 937 600 300 235 551 147 78 244 Model M N O P Q R S R U Weight kg SC06 280 100 52 61 761 523 876 562 900 470 male 137667 A001 ...

Страница 9: ...Dimensions mm SC08 SC11 Drawn as left hand unit Model A B C D E F G H I J K L SC08 2650 1771 895 751 1139 600 400 195 583 147 78 215 SC11 3211 1771 895 829 1552 600 500 195 384 147 78 234 Model M N O P Q R S T U V Weight kg SC08 360 100 52 45 761 653 1076 770 790 360 565 SC11 420 100 52 45 761 733 1492 770 790 770 683 male 137667 A001 ...

Страница 10: ...that it is protected against physical damage that can harm panels handles display etc It should be covered so that dust rain and snow cannot enter and damage the unit and its components The appliance is delivered with all necessary components wrapped in plastic on a pallet for easy transportation When transporting the Topvex SC03 11 units use a forklift placed on the gable of the unit For size SC0...

Страница 11: ...n switch As long as the main voltage is on the electrical cabinet will be kept warm also in cold climates Although the unit is turned off by the control system the current is on When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec tion doors should be easily accessible Leave free space for opening the doors and for taking out the mai...

Страница 12: ...8 Installation Fig 5 Fig 6 137667 A001 ...

Страница 13: ...ed as well to a separate tube and water lock accessories Use the enclosed connection tube which needs to be cut down to the appropriate height See table 2 how the height H corresponds to different maximum negative pressures See figure 8 for dimensions and assembly Note When installed in a non heated place the drain pipe and trap needs to be insulated well to prevent the water from freezing Fig 7 D...

Страница 14: ...e unit must be installed in the following position Fig 9 Installation position left hand unit Fig 10 Installation position right hand unit Table 3 Symbol description Symbol Description Supply air Exhaust air Outdoor air Extract air 137667 A001 ...

Страница 15: ...ted or in some other way provided with protection so that it is not possible to come in contact with the fans through the duct connections Warning Beware of sharp edges during mounting and maintenance Make sure that a proper lifting device is used Use protective clothing 1 Prepare the surface where the unit is to be mounted Make sure that the surface is flat levelled and that it supports the weigh...

Страница 16: ...ir duct figure 11 See table 4 6 5 to which terminals the sensor needs to be connected in the electrical connection box Other temperature sensors are built in to the unit from factory The supply air sensor is enclosed in the unit package on delivery Fig 11 Installed supply air sensor right hand connected unit 137667 A001 ...

Страница 17: ...air 1 Fan supply air 2 Fan extract air 3 Filter supply air 4 Filter extract air 5 Heat exchanger 6 Electric compartment 7 Damper bypass extract air 8 Damper bypass outdoor air 9 Damper bypass heat exchanger 10 Pressure sensor extract air filter extract air fan 11 Pressure sensor supply air fan supply air filter 12 Pressure sensor defrosting exchanger 13 Extract air sensor 14 Outdoor air sensor 15 ...

Страница 18: ...ation must be installed Total insulation thickness must be at least 150 mm Caution If the unit is installed in a cold place make sure that all joints are covered with insulation and tape well Duct connections duct ends should be covered during storage and installation Do not connect tumble dryers to the ventilation system 4 6 3 Silencers To avoid fan noise being transferred via the duct system sil...

Страница 19: ... sure that the mains to the unit is disconnected before performing any maintenance or electrical work All electrical connections must be carried out by an authorized installer and in accordance with local rules and regulations Topvex SC03 11 are equipped with a built in regulator and internal wiring Fig 13 Electric components Position Description 1 Regulator E 283 WEB 2 Transformer 230 24V AC 3 Te...

Страница 20: ...I 1 Temperature sensor supply air 40 Agnd UI reference neutral 412 UAI 1 UDI 1 Pressure transmitter extract air 422 UAI 2 UDI 2 Pressure transmitter supply air 44 UAI 3 UDI 3 Frost protection sensor water heating battery Use terminal 40 as reference 43 DI ref Extended running Fire alarm reference 24V DC P1 50 P2 60 B Exo line B Modbus Exo line connection P 151 P2 61 A Exo line A Modbus Exo line co...

Страница 21: ...ies for controller E283 WEB RS485 Modbus 50 51 52 or 60 61 62 RS485 BACnet 50 51 52 or 60 61 62 RS485 Exoline 50 51 52 53 or 60 61 62 63 TCP IP Exoline TCP IP Modbus TCP IP WEB TCP IP BACnet Fig 14 BMS connection on the controller 137667 A001 ...

Страница 22: ...ntrol panel is delivered connected to the Corrigo control unit situated in the electrical connection box Cable length is 10 m In case the control panel needs to be detached from the signal cable it is possible to loosen the wires on the back of the control panel figure 16 A set of self adhesive magnet strips are included in the package to facilitate installation on a metal surface 137667 A001 ...

Страница 23: ...nnections Position Description 1 Mounting holes 2 Connection block 3 Connection to brown cable 4 Connection to yellow cable 5 Connection to white cable 6 Connection to black cable 4 8 Additional equipment For information concerning additional external equipment such as valve actuators motorized dampers E tool roof units wall grilles etc see technical catalogue and their enclosed instructions For e...

Страница 24: ...Topvex SC03 11 Installation instructions 137667 en_GB 2017 05 31 A001 Systemair Sverige AB Industrivägen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com ...