5800 SE 78th St. Ocala, FL 34472
28
P: (800) 327-3015
AP20BCF200-3-XL Installation & Operations Manual
PC Connection Package
Connect to Controller - Direct Connection
The optional wireless pc communication package features:
• HACCP data download via local Wi-Fi network or peer-to-peer connection
• Remote blast chiller monitoring via Wi-Fi network
• E-mail notifications
The optional wireless pc communication package is required to connect to the controller.
The controller is set from the factory as a Wi-Fi access point. In this configuration the controller broadcasts an SSID
such as blast-chiller-xxxxxxxxxxx-wha.
Step
Description
Action
1
Open the Wi-Fi connections on the device you want to use
to access the controller
2
Connect to the SSID of the unit -
blast-chiller-xxxxxxxx-wha is the SSID that is set from the
factory. If this has been previously customized, use the
current SSID in the system.
3
Open a web browser on the device and enter 192.168.1.1
into the address bar.
4
The home screen of the controller should show up in the
browser window. You are now able to download HACCP
data, monitor the blast chiller modes and set up any
notification settings.