16
TROUBLESHOOTING
Trouble
Possible Cause
Remedy
No water
Valves are closed
Filter clogged
Open valves
Remove and clean water inlet filter (D)
Water cold
No power
Water temperature is set
too low
Check electric breaker
Check power switch on unit
Increase temperature –press “UP” button
Flow to fast to achieve desired
temperature, Slow down flow.
Water too hot
Water temperature is set
too high
Lower temperature
No hot water.
Unit
shows a
diagnostic
code.
Internal problem or
unit
went through an
automatic
safety
shutdown.
Unit will automatically reset otherwise
call our service number or a licensed
contractor for assistance.
If you need further assistance, call American Hometec, Inc. toll free service
and
support line at 1
-
800
-
295
-
8039. Please have product information including
serial number, date of purchase and error code shown on the control panel, if any,
ready when you call.
DIAGNOSTIC CODES
Code
Indication
Remedy
E2
Inlet temperature sensor error Change inlet temperature
sensor
E3
Outlet temperature sensor error Change outlet temperature
sensor
E4
Outlet temperature is too high
Lower temperature level. Error
should
disappear in a few
seconds after
correction
E5
Electric short occurred
Turn unit off and back on
after 30
seconds. If error
code remains, do not
use
the unit. Call for service
immediately
If error code does not appear any more, the
error
may be caused by external
interference
E6
unusual voltage situation
Waiting for the voltage back to usual
Содержание AHQ-TB32
Страница 5: ...5 TYPICAL INSTALLATION Figure 1 Typical Installation Figure 2A Dimensions and Clearance...
Страница 23: ...5 INSTALACI N T PICA Figura 1 Instalaci n t pica Figura 2 Dimensiones y tolerancia...
Страница 37: ...19 American Hometec Inc www AmericanHometec com 1 800 295 8039 2010 American Hometec Inc AHQ TB32 _V06d 102110...
Страница 42: ...5 INSTALLATION TYPIQUE Illustration 1 Installation typique Illustration 2 Dimensions et distances...
Страница 56: ...19 American Hometec Inc www AmericanHometec com 1 800 295 8039 2010 American Hometec Inc AHQ TB32 _ V06d 102110...