Fire or explosion hazard. Can cause property damage, servere injury or death. 

Exactly follow the warnings and the lighting instructions. 
 
1.  Before lighting, smell around the appliance area for gas. If the appliance uses LP (bottled) gas, be sure to smell next to the 

floor because LP gas is heavier than air. If you smell gas, immediately shut off the manual valve in the gas piping to the 
appliance or, on LP at the tank. Do not try to light any appliance. Do not touch any electrical switch or use the phone. Leave 
the building and call your gas supplier. If your gas supplier cannot be reached, call the fire department. 

2.  Do not force the gas control knob on the appliance. Use only your hand to turn the gas control knob. Never use any tools. If 

the knob does not operate by hand, have a qualified service technician replace the control. Force or any attempted repair 
can result in fire or explosion.  

3.  The gas conrol must be replaced if it has been flooded with water. Call a qualified service technician. 
4.  The gas control is a safety device. It must be replaced in case of any physical damage such as bent terminals, missing 

parts, stripped threads, or evidence of exposure to heat. 

 

 
IMPORTANT:

 

Follow the operating instructions provided by the manufacturer of your heating appliance. 

 

TROUBLESHOOTING

 

 
IMPORTANT:

 

Troubleshooting procedures should only be performed by an experienced qualified service technician. 
 

If the pilot will not stay lit:

 

 
1.  Confirm that the thermocouple is making tight proper conection to the valves power unit 
2.  With the pilot burning and the gas control knob turned to the PILOT position, the voltage should be18 mV for a new 

thermocouple. You must press and hold the gas control knob in the PILOT position to maintain the gas flow to the pilot. If the 
output does not meet the minimum voltage, replace the thermocouple. The power unit will hold in down to 3 mV. If the output 
of the thermocouple is below 3 mV, replace the thermocouple. 

 
If main burner does not come ON when the remote control is turned ON or the DC powered wall switch is turned ON or 
if the DC motor drive on models AF-1025 or AF-1125 will not run and turn the burner ON when the button on the remote 
transmitter is pressed: 

 

 
1.  Confirm that the pilot is lit. 
2.  Confirm that the gas control knob is in the ON position. 
3.  If a DC powered switch or remote control is used to turn the valve ON/OFF confirm that the switch or remote is in the ON 

position. 

4.  Check the connections on the RED and BLACK wires from the remote receiver. 
5.  Check the DC power supply of the remote receiver or the wall switch. 
 

 
 
 
 
 
 
 

American Flame, Inc.   9230 Conservation Way   Fort Wayne, IN  46809

 

Phone (260) 459-1703 

 

Fax (260) 459-1592 

 

 

 

 

 

 

 

Limited Warranty 

 

 

American Flame, Inc. warrants the AF-1000 Valve series for 12 months from the date of purchase or installation to the original 
purchaser to be free from defects in materials and workmanship. Damage to the AF-1000 Valve caused by accident, misuse, 
abuse, or installation error, whether preformed by a contractor, service company, or owner, is not covered by this warranty. 
American Flame will not be responsible for labor charges and/or damage incurred in installation, repair, replacement, or for 
incidental or consequential damage. Some states, provinces, and nations do not allow exclusion or limitations of incidental or 
consequential damages, so the above limitations or exclusions may not apply. This warranty gives you specific legal rights. You 
may also have other rights that vary by state, province, or nation.

 

 

f i r e - p a r t s . c o m

Содержание AF-1000 Series

Страница 1: ...pe of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Mounting Power unit powered by 30mv thermocouple CSA rated capacity 80 000 BTU hr at 1 wc pres...

Страница 2: ...lead Option 8mm x1 0 connection Ventfree Thermocouple location Back of valve Ambient Temperature Range 0 0 F to 225 0 F 18 0 C to 107 0 C Voltage 30 mV Thermocouple Approvals CSA International Report...

Страница 3: ...REV 1 9 2010 Page 3 of 9 DIMENSIONS fire parts com...

Страница 4: ...rce or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 1000 gas control where it cannot be affected by steam cleaning high humidity dripping water co...

Страница 5: ...ents main gas flow through the valve 2 ON Permits main burner and pilot flow Gas control and remote control of main burner gas flow 3 PILOT Opens pilot valve and allows gas flow to pilot burner NOTE W...

Страница 6: ...stment per test standard Shut off Procedure 1 To shut OFF the system turn the gas control knob clockwise to the OFF position This action will close the main gas valve and disengages the safety pilot v...

Страница 7: ...property damage servere injury or death 1 Stand away from the main burner while lighting Hidden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution...

Страница 8: ...explosion hazard Can cause property damage severe injury or death Do not attempt to take apart the gas control or to clean it Improper assembly and cleaning can cause unreliable operation Regular pre...

Страница 9: ...mocouple You must press and hold the gas control knob in the PILOT position to maintain the gas flow to the pilot If the output does not meet the minimum voltage replace the thermocouple The power uni...

Отзывы: