american flame AF-1000 Series Скачать руководство пользователя страница 4

 

 

 

REV. 1/9/2010    

Page 4 of 9

   

INSTALLATION

 

 

When Installing this Product…. 

 

  Read these instructions carefully. Failure to follow these instructions completely could damage the product or cause a 

hazardous condition. 

  Check the ratings given in the instructions and on the product to make sure the AF-1000 Gas Control is suitable for your 

application. 

  Installer must be a trained, experienced service technician. 

 

After installation is complete, check out product operation as provided in these instructions

 
 
 

Oxygen depletion hazard. Can cause injury or death due to asphyxiation. 

1.  Use only vented gas pilot assemblies on vented appliances. 

2. 

Use only unvented pilot assemblies on unvented appliances.

 

 
 
 
 
Fire or explosion hazard. Can cause property damage, servere injury or death. Follow these warnings exactly: 

1.  Disconnect power before wiring to prevent electrical shock or equipment damage. 
2.  To avoid dangerous accumlation of fuel gas, turn off gas supply at the appliance service valve before starting installation, 

and perform a Gas Leak Test after installation is complete. 

3.  Always install the sediment tap in the gas supply line to prevent contamination of the gas control. 
4.  Do not force the gas control knob. Use only your hand to turn the gas control knob. Never use any tools. If the gas control 

knob does not operate by hand, a qualified service technician should replace the gas control. Force or any attempt to  repair 
the gas control valve can result in fire or explosion. 

 

Location:

 

Locate the AF-1000 gas control where it cannot be affected by steam cleaning, high humidity, dripping water, corrosive 
chemicals, dust or grease accumulation or excessive heat. To assure proper operation, follow these guidelines: 
 
1.  Locate gas control in well-ventilated area. 
2.  Mount gas control high enough to avoid exposure to flooding or splashing water. 
3.  Assure the ambient temperature does not  exceed the ambient temperature ratings for each component. 
4.  Cover gas control if appliance is cleaned with water, steam, or chemicals or to avoid dust and grease accumulation. 
5.  Avoid locating gas control where exposure to corrosive chemical fumes or dripping water is likely. 

 
Install Piping to Gas Control 

 

 

 

 

 

All piping must comply with the local codes and ordinances or with the  
National Fuel code (ANSI Z223.1 NFPA No. 54) which ever applies.  
Tubing installation must comply with approved standards and practices. 
1.  Use new, properly reamed pipe free from chips, When tubing is used,  

assure the ends are square, deburred and clean. All tubing bends  
must be smooth and without deformation. 

2.  Run pipe or tubing to the control. If tubing is used, obtain a tube-to-pipe  

coupling to connect the tubing to the control. 

3.  Install sediment trap in the supply line to the gas control. See Figure #1 
 
 
 

 

Gas Leakage Hazard. Failure to follow precautions can result in a  
gas-filled work area. 
 

Shut off the main gas supply before removing end cap. Test for gas leakage  
when installation is complete. 

 

 

 

 

 

 

 

 

 

Figure #1 

 

 

 

 

f i r e - p a r t s . c o m

Содержание AF-1000 Series

Страница 1: ...pe of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Mounting Power unit powered by 30mv thermocouple CSA rated capacity 80 000 BTU hr at 1 wc pres...

Страница 2: ...lead Option 8mm x1 0 connection Ventfree Thermocouple location Back of valve Ambient Temperature Range 0 0 F to 225 0 F 18 0 C to 107 0 C Voltage 30 mV Thermocouple Approvals CSA International Report...

Страница 3: ...REV 1 9 2010 Page 3 of 9 DIMENSIONS fire parts com...

Страница 4: ...rce or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 1000 gas control where it cannot be affected by steam cleaning high humidity dripping water co...

Страница 5: ...ents main gas flow through the valve 2 ON Permits main burner and pilot flow Gas control and remote control of main burner gas flow 3 PILOT Opens pilot valve and allows gas flow to pilot burner NOTE W...

Страница 6: ...stment per test standard Shut off Procedure 1 To shut OFF the system turn the gas control knob clockwise to the OFF position This action will close the main gas valve and disengages the safety pilot v...

Страница 7: ...property damage servere injury or death 1 Stand away from the main burner while lighting Hidden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution...

Страница 8: ...explosion hazard Can cause property damage severe injury or death Do not attempt to take apart the gas control or to clean it Improper assembly and cleaning can cause unreliable operation Regular pre...

Страница 9: ...mocouple You must press and hold the gas control knob in the PILOT position to maintain the gas flow to the pilot If the output does not meet the minimum voltage replace the thermocouple The power uni...