american flame AF-1000 Series Скачать руководство пользователя страница 6

 

 

 

REV. 1/9/2010    

Page 6 of 9

   

Pilot Gas and Lighting Procedure 

 

 

 

 

 

 

 

  Turn the gas control knob counterclockwise                   to the PILOT position, push the gas control knob IN and HOLD in 

position.

 

This will open the pilot valve and allows gas to flow to the pilot burner. 

 

 

  Light the pilot burner while holding the gas control knob in until a strong pilot flame is present. (Approximately 60 seconds) 

 

  Release the gas control knob. The gas control knob will hold in and engages the valve power unit. 

 

 

  Turn the gas control knob counter clockwise                  to the ON position, the main burner valve will open and the main 

burner will ignite.  

 
 

NOTE: Gas controls with model number AF-1000 for vented to decrease the pilot flame turn the pilot adjustment screw 
clockwise. To increase the pilot flame turn the pilot adjustment counter clockwise. 

 

NOTE: Gas controls with model number AF-1100 for vent free applications have NO pilot adjustment, per test standard. 

 
Shut off Procedure

 

 
1.  To shut OFF the system, turn the gas control knob clockwise               to the OFF position. This action will close the main 

gas valve and disengages the safety pilot valve. However the power unit must drop out before the lighting sequence can 
begin again. This may take as much as 3 minutes. 

 
2.  To relight the pilot, follow the steps in the Pilot Gas and Lighting Procedure section. 
 

 
Pilot Burner Connections 

 
This gas control uses a pilot burner with a thermocouple, the connections are as follows: 
 
1.  Connect the pilot tubing fitting into the gas control connection and tighten. (Use caution on brass connectors) Note: Figure 

#7 & #8  

2.  Connect thermocouple into power unit at the back of the gas control.  Note: Figure #8   
 
NOTE:  A standard thermocouple or quick drop out thermocouple with 11/32-32 UNS threads and Ventfree ODS thermocouple 
with 8mm x 1.0 thread can be used. Note: Figure #8 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure #7 

 

 

 

 

 

 

Figure #8 

 

 

 

 

 

 

 

 

 

PILOT ASSEMBLY

AF-1000 Valve

Thermocouple

   Connection

Pilot Connection

 

 3/8” NPT

OUTLETS

3/8” NPT

  INLET

THERMOCOUPLE

   CONNECTION

PILOT FITTING

CONNECTION

 

f i r e - p a r t s . c o m

Содержание AF-1000 Series

Страница 1: ...pe of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Mounting Power unit powered by 30mv thermocouple CSA rated capacity 80 000 BTU hr at 1 wc pres...

Страница 2: ...lead Option 8mm x1 0 connection Ventfree Thermocouple location Back of valve Ambient Temperature Range 0 0 F to 225 0 F 18 0 C to 107 0 C Voltage 30 mV Thermocouple Approvals CSA International Report...

Страница 3: ...REV 1 9 2010 Page 3 of 9 DIMENSIONS fire parts com...

Страница 4: ...rce or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 1000 gas control where it cannot be affected by steam cleaning high humidity dripping water co...

Страница 5: ...ents main gas flow through the valve 2 ON Permits main burner and pilot flow Gas control and remote control of main burner gas flow 3 PILOT Opens pilot valve and allows gas flow to pilot burner NOTE W...

Страница 6: ...stment per test standard Shut off Procedure 1 To shut OFF the system turn the gas control knob clockwise to the OFF position This action will close the main gas valve and disengages the safety pilot v...

Страница 7: ...property damage servere injury or death 1 Stand away from the main burner while lighting Hidden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution...

Страница 8: ...explosion hazard Can cause property damage severe injury or death Do not attempt to take apart the gas control or to clean it Improper assembly and cleaning can cause unreliable operation Regular pre...

Страница 9: ...mocouple You must press and hold the gas control knob in the PILOT position to maintain the gas flow to the pilot If the output does not meet the minimum voltage replace the thermocouple The power uni...

Отзывы: