american flame AF-1000 Series Скачать руководство пользователя страница 5

 

 

 

REV. 1/9/2010    

Page 5 of 9

   

Install Control

 

 

 

 

 

 

 

 

 

 

 

 

 
 
1.  Mount control 0 to 90 degrees in any direction, from the upright position  

of the gas control knob, including vertically. 

2.  Mount the control so gas flow is in the direction of the arrow on the side  

 Figure #2 

or back of the control. 

3.  Thread pipe 5/16 in. into the control. Do not inset deeper than 3/8 in. Valve  

distortion or malfunction can result if the pipe is inserted too deeply.   

 

4.  Apply a moderate amount of good quality pipe compond (do not use Teflon  

tape) to pipe only, leaving two (2) end threads bare. On LP installations,  

 

use compond resistant to LP gas. See Figure #2 

5.  Remove plastic dust  seals over the control Inlet and Outlet if necessary. 
6.  Connect pipe to control Inlet and Outlet. Use wrench on either side of the  

pipe outlet. See Figure #3  
 

 
 
 

 

 

 

 

 

 

 

 

Figure #3 

 

 

 

Gas Control Knob Settings 

 
Gas control knob settings are as follows: 
 
1.  OFF:  

Prevents main gas flow through the valve. 

2.  ON  

Permits main burner and pilot flow. Gas control and remote control of main burner gas flow. 

3.  PILOT: 

Opens pilot valve and allows gas flow to pilot burner. 

NOTE:  When remote controls and wired DC operated hearth/wall switches are used, the gas control knob must be in the ON 
position. Note Valve front (Face) views in Figures #4 & #5 & #6 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
Figure #4 

 

 

 

 

 

 

 

 

Figure #5 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Figure #6                                                                        Figure #6-A

 

 
 
 
 
 

 

GAS CONTROL

KNOB

PILOT

ADJUSTMENT SCREW

(NOT ADJUSTABLE ON

VENTFREE MODELS)

FACE VIEW OF GAS CONTROL WITH ON/OFF DC MOTOR DRIVE

KNOB POSITION

    INDICATOR

ON/OFF/VARIABLE

DC MOTOR DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS CONTROL

KNOB

PILOT

ADJUSTMENT SCREW

(NOT ADJUSTABLE ON

VENTFREE MODELS)

FACE VIEW OF GAS CONTROL WITH OUT SOLENOID

KNOB POSITION

    INDICATOR

 

GAS CONTROL

KNOB

PILOT

ADJUSTMENT SCREW

(NOT ADJUSTABLE ON

VENTFREE MODELS)

FACE VIEW OF GAS CONTROL WITH SOLENOID

KNOB POSITION

    INDICATOR

   ON/OFF

SOLENOID

 

 

GAS CONTROL

KNOB

PILOT

ADJUSTMENT SCREW

(NOT ADJUSTABLE ON

VENTFREE MODELS)

FACE VIEW OF GAS CONTROL WITH ON/OFF STEP MOTOR

KNOB POSITION

    INDICATOR

    ON/OFF/HI/LO

STEP MOTOR DRIVE

 

f i r e - p a r t s . c o m

Содержание AF-1000 Series

Страница 1: ...pe of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Mounting Power unit powered by 30mv thermocouple CSA rated capacity 80 000 BTU hr at 1 wc pres...

Страница 2: ...lead Option 8mm x1 0 connection Ventfree Thermocouple location Back of valve Ambient Temperature Range 0 0 F to 225 0 F 18 0 C to 107 0 C Voltage 30 mV Thermocouple Approvals CSA International Report...

Страница 3: ...REV 1 9 2010 Page 3 of 9 DIMENSIONS fire parts com...

Страница 4: ...rce or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 1000 gas control where it cannot be affected by steam cleaning high humidity dripping water co...

Страница 5: ...ents main gas flow through the valve 2 ON Permits main burner and pilot flow Gas control and remote control of main burner gas flow 3 PILOT Opens pilot valve and allows gas flow to pilot burner NOTE W...

Страница 6: ...stment per test standard Shut off Procedure 1 To shut OFF the system turn the gas control knob clockwise to the OFF position This action will close the main gas valve and disengages the safety pilot v...

Страница 7: ...property damage servere injury or death 1 Stand away from the main burner while lighting Hidden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution...

Страница 8: ...explosion hazard Can cause property damage severe injury or death Do not attempt to take apart the gas control or to clean it Improper assembly and cleaning can cause unreliable operation Regular pre...

Страница 9: ...mocouple You must press and hold the gas control knob in the PILOT position to maintain the gas flow to the pilot If the output does not meet the minimum voltage replace the thermocouple The power uni...

Отзывы: