REV. 1/9/2010
Page 7 of 9
DC powered feature of the AF1000
The AF-1000 has a non-leak safety feature that allows the installation of an ON/OFF solenoid. Note: Figure #9
With the use of this DC powered latching ON/OFF solenoid allows the use of a DC powered switch or remote control (Model
CON 1001)
NOTE:
The AF-1025 and AF-1125
(ONLY)
do not have a non-leak safety feature. This model comes from the factory with the
ON/OFF DC motor Drive per installed Note: Figure #10
With the use of this DC powered ON/OFF Motor Drive the valve will operate ON/OFF
(ONLY)
with the use of a remote control
(Model RCAF 1005)
Note
:
If the Hi/Lo Step Motor used on the AF-1035 and AF-1135 valve the (Motel AF-4000MOT) model must be used.
If
the Hi/Lo Step Motor used on the AF-1030 and AF-1130 valve the (Motel AF-1000MOT) model must used. Each model
requires a unique operating control transmitter and receiver specifically set-up for the desired Hi/Lo increments
required by the burner installed in the appliance that the AF-1000 valve system is used on.
Figure # 9
Figure #10
Figure #11
Fire or explosion hazard. Can cause property damage, servere injury or death.
1. Stand away from the main burner while lighting, Hidden gas leaks can cause flashbacks in the appliance.
2. Check for gas leaks with rich soap and water solution any time work is done on a gas system.
Gas Leak Test
1. Paint the pipe connectors upstream of the gas control with rich soap and water solution, Bubbles indicate a gas leak.
2. If a leak is detected, tighten the pipe connections.
3. Light the main burner.
4. With the main burner in operation, paint the pipe joints (including adapters) with rich soap and water solution.
5. If another leak is detected, tighten the adapter screws, joints, and pipe conections.
6. Replace part if leak cannot be stopped.
GAS CONTROL
KNOB
PILOT
ADJUSTMENT SCREW
(NOT ADJUSTABLE ON
VENTFREE MODELS)
FACE VIEW OF GAS CONTROL WITH SOLENOID
KNOB POSITION
INDICATOR
ON/OFF
SOLENOID
1/4” Male
Connectors
GAS CONTROL
KNOB
PILOT
ADJUSTMENT SCREW
(NOT ADJUSTABLE ON
VENTFREE MODELS)
FACE VIEW OF GAS CONTROL WITH ON/OFF DC MOTOR DRIVE
KNOB POSITION
INDICATOR
ON/OFF/VARIABLE
DC MOTOR DRIVE
1/4” Male
Connectors
GAS CONTROL
KNOB
PILOT
ADJUSTMENT SCREW
(NOT ADJUSTABLE ON
VENTFREE MODELS)
FACE VIEW OF GAS CONTROL WITH ON/OFF STEP MOTOR
KNOB POSITION
INDICATOR
ON/OFF-HI/LO
STEP MOTOR
(AF-1000MOT & AF-4000MOT)
4 pin
Connector