Wiring Configurations
In Vicon systems where the domes support loop through, daisy chain the SpeedDome Ultra VII
domes off the last Vicon dome in the communications chain.
Figure F-1: SpeedDome Ultra VII dome loop-through wiring from Vicon dome
To controller or
other domes
In Out In Out
Command
Response
Vicon dome
SpeedDome
Ultra VII dome
SpeedDome
Ultra VII dome
In Vicon systems where the domes support RS-485 daisy chaining, daisy chain the SpeedDome Ultra
VII domes off the controller or one of the Vicon domes in the communications chain.
Figure F-2: SpeedDome Ultra VII dome RS-485 wiring from Vicon dome
To controller or
other domes
+ -
+ -
R+ R- T+ T-
R+ R- T+ T-
In Out
Command Response
Vicon dome
SpeedDome
Ultra VII dome
SpeedDome
Ultra VII dome
Vicon Protocol Command Summary
F–5