Intellex
®
Digital Video Management System Installation and Operating Instructions
79
Record Mode Setup
MORE>>>
RECORD MODE
SETUP
The
Record Mode
screen lets you configure how the unit records
images during regular (nonalarm) operation. You must possess
the
Setup Record
privilege to access it (see
1.
From the main screen, click the
Setup
button. The
Setup
Options
screen appears (see
).
2.
Click the
Record Mode
button. The
Record Mode
screen
appears. Select
Linear
or
Circular
record mode.
Linear —
In linear mode, the unit records from the beginning to
the end of the image database. When the database is full, the unit
stops recording and displays an option screen. The operator must
choose one of the following options:
•
Perform a backup immediately.
•
Postpone archiving and recording until later.
•
Continue recording images at the beginning of the database,
which overwrites older images.
After clearing the option screen, the operator must select
Begin
Record
on the
Utility Options
screen to restart unit recording. (See
and
for more information.)
Notify when ____% full —
In linear mode, the unit notifies the
operator when the image database reaches a certain level (
50%
to
100%
). The default is
75%
.
NOTE: This option is disabled unless Linear is selected.
•
Move the slide control to the left to decrease the percentage
in increments of five. Select a low percentage to display the
warning message when the database has a lot of available
space.
•
Move the slide control to the right to increase the percentage
in increments of five. Select a high percentage to display the
warning message when the database has less available space.
NOTE: When the image database is full and Linear is selected,
recording stops and an option screen appears.