Database Full
When the image database is full, and none of the images have
been archived, the unit stops recording. It flashes the
Alarms
indicator on the front panel. It also energizes alarm output 16 if
the
Message Alert
option is selected (see
). Then it
displays the following screen:
NOTE: This screen only appears when Linear is selected on the
Record Mode screen.
Select one of the following options and click
OK
:
Continue at beginning. —
Select this option to continue
recording images from the beginning of the image database.
When the database becomes full, the unit behaves as if circular
mode is selected, recording over the oldest images.
When you select this option, a warning screen appears. If the
database contains unarchived images, refer to
Otherwise refer to
.
Begin recording later. —
Select this option if you do not want to
record any images to the database until later. Click the
Begin
Record
button on the
Utility Options
screen to start recording
images (see
).
Help —
Click to display online help for the screen.
Unarchived Images
Before it starts recording at the beginning of the database, the
unit confirms your decision. If the database contains unarchived
images, select one of the following options and click
OK
:
Select
Yes
to start recording again. Select
No
to cancel the
operation and return to the database full screen (see
). Click
Help