Alarm and Relay

Connections

The back panel of the AD32 Video Matrix Switcher
provides eight alarm contact inputs, an external
frequency synchronization input, and contact
terminations for an internal alarm-activated relay.
You can program the Form-C internal relay to
activate during alarms for control of a VCR or other
alarm response device.

Figure 4.  Alarm/Relay Connections

1           3         5           7         9       11       13       15       17       19       21       23      25       27       29       31

 

2         4         6        8        10       12       14       16       18       20      22       24       26       28       31       32

1   2  3   4   5   6   7   8             SI      NO NC C

1           2            3          4            5

1             2             3

RS232 PORTS

MONITORS

ALARMS

RELAY

120V
60Hz

CAMERAS

1   2  3   4   5   6   7   8             SI      NO NC C

ALARMS

RELAY

The following is a description of the alarm and
relay connector pins.

Pin

Description

1

Ground

2

Alarm  1

3

Alarm  2

4

Alarm  3

5

Alarm  4

6

Alarm  5

7

Alarm  6

8

Alarm  7

9

Alarm  8

10

Ground

11

External Sync Ground

12

External Sync Input

13

Ground

14

Relay–Normally Open

15

Relay–Normally Closed

16

Relay–Common

Connections

Alarms

 

Alarm contact closures must have a resistance
of 500 Ohms or less.

 

Connect alarm contacts to inputs 1 through 8
(pins 2 through 9).

 

Connect alarm contact returns to Ground (pin
1 or 10).

External Sync

 

External sync input signal must be 1-5Vrms,
50/60Hz.

 

Connect external sync input to 

SI

 (pin 12).

 

Connect external sync ground to Ground (pin
11).

Relay

 

Connections for the internal relay are normally
open (NO), normally closed (NC), and
common (C). The relay contact ratings are
0.6A @ 120Vac / 0.3A @ 240Vac or 2.0A @
30Vdc.

 

Connect an alarm-response device requiring a
normally open circuit to 

NO

 (pin 14) and 

C

 (pin

16).

 

Connect an alarm-response device requiring a
normally closed circuit to 

NC

 (pin 15) and 

C

(pin 16).

Pin

Pin 16

Video Matrix Switcher—Rear Panel

120Vac, 60Hz or
240Vac, 50Hz

Содержание ADS32X

Страница 1: ...power transformer cable and the SensorNet data cable and if required the data cable to EIM 2 to the compression connector and connect it to J3 on each EIM 5 Wire the DB9 connector to the data cable Se...

Страница 2: ...OUCH TRACKER Secondary TOUCH TRACKER Video Matrix Switcher EIM DB9 M COLOR PIN FUNCTION Green 3 Receive Red 2 Transmit Orange 5 Ground NOTE The system supports up to 2 controllers Terminate E1 on the...

Страница 3: ...ss Next to toggle between using the primary unit for SensorNet polling and alarm monitoring or as the secondary unit with limited user functionality 5 Press Menu to reset the controller as a primary o...

Страница 4: ...sorNet Ping Test 1 Use the number buttons to select a dome to test then press Camera 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the zoom line 1 or focus line 2 button t...

Страница 5: ...ach EIM 7 Wire the DB9 connector to the data cable See the tables on page 2 Assemble the hood onto the DB9 connector 8 Connect the data cable to J1 on the EIM to the HP0047 terminal box 9 Install a fe...

Страница 6: ...1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 1 2 3 4 5 6 7 8 SI NO NC C 1 2 3 4 5 1 2 3 RS232 PORTS MONITORS ALARMS RELAY 120V 60Hz CAMERAS Transformer J3 Wiring Pin Function 1 N A 2 24Vac A 3 Ground...

Страница 7: ...2 Alarm 1 3 Alarm 2 4 Alarm 3 5 Alarm 4 6 Alarm 5 7 Alarm 6 8 Alarm 7 9 Alarm 8 10 Ground 11 External Sync Ground 12 External Sync Input 13 Ground 14 Relay Normally Open 15 Relay Normally Closed 16 R...

Отзывы: