ADS32X TOUCH TRACKER with VIDEO MATRIX SWITCHER
8000-1691-02, Rev. A
INSTALLATION INSTRUCTIONS 3
Calibrating the Tracker Ball
1. Press
Menu
. The
Calibration
menu option
will appear on the first line.
2. Press the zoom (line 1) or focus (line 2) button
to select the
Calibration
menu option.
3. Follow the instructions on the LCD screen.
4. Press
Menu
to exit.
If you do not follow each instruction on the screen, the
dome may not function properly. Re-calibrate the
Tracker Ball if the dome does not pan or tilt properly.
Calibration is only for the Touch Tracker controller.
Resetting a Dome
1. Use the number buttons to select the dome to
reset, then press Camera.
2. Press Menu.
3. Using the Tracker Ball, scroll down to
Reset Dome.
4. Press the zoom (line 1) or focus (line 2) button
to select the Reset Dome menu option.
The Touch Tracker will send a request to the selected
dome to reboot.
Switching Primary and
Secondary Functions between
Controller Units
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Tog Primary/2nd.
3. Press the zoom (line 1) or focus (line 2) button
to select the Tog Primary/2nd menu option.
4. Press Next to toggle between using the primary
unit for SensorNet polling and alarm monitoring
or as the secondary unit with limited user
functionality.
5. Press Menu to reset the controller as a primary
or secondary unit.
The controller will reboot and return to the Camera
Control Mode.
Switching Zoom and Focus
Functions between Left and
Right Buttons
1. Press Menu.
2. Using the Tracker Ball, scroll down to
Tog Zoom/Focus.
3. Press the zoom (line 1) or focus (line 2) button
to select the Tog Zoom/Focus menu option.
4. Press Next to switch the Zoom and Focus
functions between the right and left buttons.
5. Press Menu to save the configuration and exit.
Adjusting V-Phase
1. Press Menu.
2. Using the Tracker Ball, scroll down to Adjust V-
Phase.
3. Press the zoom (line 1) or focus (line 2) button
to select the Adjust V-Phase menu option.
4. Press Next or Prev to observe V-Phase through
the oscilloscope or Fluke scope.
5. Press Menu to exit.
Off-line domes or fixed cameras will generate a warning
beep and disallow use of the V-Phase utility. For
additional information on adjusting V-Phase, see the
Service section of the AD32 Installation and Service
Manual.
Figure 2. Ferrite Core Attachment
0 in
2.54 - 3.81 cm
(1" - 1.5")
Ferrite Core
RJ45
DB9(M)
Place 1 loop into core
slot; close core halves;
gently pull cable to
tighten loop.