AK INSTALLATION AND SERVICE INSTRUCTIONS
4211-1551 06/18/18 Technical Support: 1-425-951-1120 1-800-363-0251 [email protected] Page
18
of
20
SECTION 7. INITIAL START
1.
Assure power and water are on. Press the control’s ON/OFF switch. The control should light then the water valve
should turn on to fill the steamer.
While filling, check for leaks.
2.
After the tank has filled to a safe level, the heating elements will turn on. Allow about 10 minutes for the steam to
appear in the steam room.
3.
Once the steam is visible, use the control to turn the bath off. The steam should stop within a couple minutes and
the water valve should turn off. The control should not be lit.
4.
Press the ON/OFF switch again. The control should light.
5.
Within one minute the unit should again produce steam. It should call for water once every two minutes or more
depending on its power rating. It’s normal for the flow of steam out the steam head to slow for up to 10 seconds
each time the unit calls for water.
6.
The unit will shut down automatically in 30 minutes if an R30 control is used, or up to 60 minutes if the K60 or
KT60 Control is used (depending on its TIME setting). When the time runs out the steam will stop and there should
not be any water flow. The control should not be lit.