AK INSTALLATION AND SERVICE INSTRUCTIONS
4211-1551 06/18/18 Technical Support: 1-425-951-1120 1-800-363-0251 [email protected] Page
15
of
20
SECTION 5. BATH CONTROLS INSTALLATION (continued)
3A INSTALL GENERATOR CONTROL (K60 OR KT60):
The low voltage K60 control can be mounted directly to a finished wall either
inside or outside the steam room. The low voltage KT60 control must be
mounted inside the steam room.
See step 1 of this section.
1. Use a 2” (50 mm) hole saw, to drill a hole in the finished wall where the
control is to be mounted (the control cable should already be roughed-in to
this location).
This must be inside the room for KT60 controls.
2. With the decorative cover removed from the control switch assembly,
insert the two control mounting screws through the control housing (you may
need to punch through skinned holes) and screw a few turns into the
mounting bracket. Locate the control cable and plug it into the back of the
control housing. See Diagram 11.
Run a bead of 100% silicon caulk in-between the 2 ridges around the
perimeter on the back of the control housing. See diagram 11.
Insert the mounting bracket into the wall cavity by first pushing with the
control housing and then with a hard flat surface on the control housing
mounting screws which extend out through the control face. See Diagram 11
Once the mounting bracket has been inserted into the finished wall, center
the control and tighten the mounting screws to draw the control housing
securely against the finished wall. Do not over tighten the mounting screws.
Add a little silicone over the screw heads to seal the screw holes.
3. Install the decorative cover plate by sliding the top of the cover plate over
the tab on the top of the control housing and pushing on the bottom of the
cover plate to complete the snap fit. See Diagram 11.
4. Route the generator end of the control cable through a knockout in the end
of the generator using the strain relief provided. Plug the control cable into
the S60A or S60B connector on the steamer’s circuit board (top edge, right
end). See diagram 10.
Note:
for steam bath temperature control, a K60 and a wall mounted sensor
or a KT60 (with built in sensor) must be installed. Only one KT60 may be
installed. You may combine two K60s or a K60 with a KT60.
OPTIONAL SECONDARY CONTROL
: (
For use with K60 or KT60 only
!) As an option, a second K60 control or an
R30K may be installed with a K60 or KT60 to provide ON/OFF control both inside and outside the steam room. The
second control should be installed as described in above, with the second K60 control cable plugged into connector
S60B or install R30K per 3B (below) and connect to the S30B jack. Do Not use an R30i with other controls.
3B. INSTALL GENERATOR CONTROL (R30K):
The R30K low voltage control can be mounted directly to a finished wall either inside or outside the steam room.
T
he R30K does not control the temperature in the steam room.
Use a 1-1/2” (36 mm) hole saw to drill a hole in the finished steam room wall where the control is to be mounted
(the control cable should already be roughed-in to this location). See Diagram 13
DIAGRAM 11
WALL
HOUSING
COVER PLATE
SILICONE