![Amcrest IP4M-1048EB Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/amcrest/ip4m-1048eb/ip4m-1048eb_user-manual_2921431057.webp)
57
Missing Object
Missing Object allows the user to set a region around an object and if the object is moved or missing from the set
region an alarm will be triggered. Below is a screenshot of the Missing Object menu:
Below is a description of the features in this menu:
No.:
Provides the order in which the IVS rules will be displayed in the menu.
Name:
Allows the user to customize a name for their rule. Double click the name in the Rule column to modify.
Schedule:
Allows the user to set a schedule in which the IVS rule will be triggered.
A Schedule must be set for IVS
rules to function
.
Duration:
Allows the user to set a specific time before the missing object triggers an event. The default is 10
seconds however it can be modified up to 3600 seconds.
Record:
This checkbox allows the user to enable the camera to record video when an IVS event is triggered.
Record Delay
: This field specifies, in seconds, how long the delay between IVS events should be. The default is 10
seconds however this can be modified between 10~300 seconds.
Send Email:
This checkbox allows the user to enable the camera to send an email when an IVS event is triggered.
Snapshot
: This checkbox allows a snapshot of the IVS event to be sent via Email when triggered.
Draw Rule
: This option allows the user to use their mouse to customize (draw) a rule/area on the live monitoring
screen. This will be the area or line in which an IVS rule will be triggered.
Clear:
This option is used to clear the drawn rule set on the live monitor screen.
Target filter:
Sets a maximum and minimum pixel size in which an event will be triggered.
Draw Target:
Allows the user to set a target area on the live monitor screen.
An IVS event will not occur outside
the target box.
Clear:
Clears the modified target area to draw the target area on the live monitoring screen.
Pixel Counter
: Used to measure and set the number of pixels in the target area on the live monitoring screen.