20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SMD23E2 and SMD24E2 User Manual
C
OMMAND
M
ODE
D
ATA
F
ORMAT
85
Input Data Format (continued)
Status Word 0 Format (continued)
Bit 13: Configuration_Error –
“1” on power up before a valid configuration has been written to the
SMD23E2 or SMD24E2, or after any invalid configuration has been written to the unit. “0” when
the unit has a valid configuration in memory.
When in Command Mode, bit 13 of word 0 is set to “1” when there is a configuration error.
When in Configuration Mode, bit 13 of word 0 is set to “1” when stall detection is enabled.
When using the state of bit 13 of word 0 in your logic, always include the state of bit 15 of
word 0 to assure that you are only acting on the bit when in the proper mode.
Bit 12: Command_Error –
“1” when an invalid command has been written to the SMD23E2 or SMD24E2.
This bit can only be reset by the
Reset_Errors
bit, Command Word 0, Bit 10.
Bit 11: Input_Error –
“1” when:
Emergency Stop input has been activated
Either of the End Limit Switches activates during any move operation except for homing
Starting a Jog Move in the same direction as an active End Limit Switch
If the opposite End Limit Switch is reached during a homing operation.
This bit is reset by a
command. The format of the command is given on page 81.
Bit 10: Position_Invalid –
“1” when:
A configuration is written to the SMD23E2 or SMD24E2
The motor position has not been preset or the machine has not been homed
The network connection has been lost and re-established
An Immediate or Emergency Stop has occurred
An End Limit Switch has been reached
A motor stall has been detected.
Absolute moves cannot be performed while the position is invalid.
Bit 9:
Waiting_For_Assembled_Segment –
The SMD23E2 or SMD24E2 sets this bit to tell the host that
it is ready to accept the data for the next segment of your assembled move profile. Its use is
explained in the
section of this manual starting on page 40.
Bit 8:
In_Assembled_Mode –
The SMD23E2 or SMD24E2 sets this bit to signal the host that it is ready to
accept assembled move profile programming data. Its use is explained in the
section of this manual starting on page 40.
Bit 7: Move_Complete –
Set to “1” when the present Absolute, Relative, Jog, Registration, or Assembled
Move command completes without error. This bit is reset to “0” when the next move command is
written to the SMD23E2 or SMD24E2, when the position is preset, or a Reset Errors command is
issued to the unit. This bit is also set along with the
Command_Error
bit (Bit 12 of this word), when
any Jog Move or Registration Move parameters are outside of their valid ranges. This bit is not set
on a command error for any other type of command. Finally, this bit is not set at the end of a homing
operation.
Bit 6: Decelerating –
Set to “1” when the present move is decelerating. Set to “0” at all other times.
Bit 5: Accelerating –
Set to “1” when the present move is accelerating. Set to “0” at all other times.
Содержание SMD23E2 Series
Страница 10: ...ABOUT THIS MANUAL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 44: ...MOTION CONTROL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Страница 54: ...CALCULATING MOVE PROFILES SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Страница 68: ...CONFIGURATION MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 68 Notes...
Страница 88: ...COMMAND MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 124: ...ETHERNET IP EXPLICIT MESSAGING SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 124 Notes...
Страница 128: ...MODBUS TCP CONFIGURATION SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 128 Notes...
Страница 134: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...