20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SMD23E2 and SMD24E2 User Manual
C
ONFIGURATION
M
ODE
D
ATA
F
ORMAT
65
Output Data Format (continued)
Configuration Word 1 Format
Figure R5.2 Configuration Mode: Config Word Format
Bit 15: Reserved –
State ignored.
Bits 14 - 12: Reserved –
Must equal zero.
Bit 11: Read_Present_Configuration –
If this bit is set when you enter Configuration Mode, the unit
responds by placing the present configuration data in the Network Input Data. You cannot write new
configuration data to the unit while this bit is set. The format of the Configuration Data is given in the
section of this chapter, starting on page 66.
Bit 10: Save_Present_Configuration –
An SMD23E2 or SMD24E2 will store its configuration data to
flash memory when this bit makes a 0
1 transition. The validity of the configuration data is checked
before being written. If the data is not correct, the transition on this bit is ignored. If the write to flash
completes successfully, the unit will write 16#AAAA into the last word of the Network Input Data
and the Module Status LED will start flashing green. If the write is unsuccessful, the unit will write
16#EEEE into the last word of the Network Input Data and the Module Status LED will start flashing
red. Once the unit issues its response to the Save_Present_Configuration command, it stops respond-
ing to commands and you must cycle power to the unit. This design decision prevents the SMD23E2
or SMD24E2 from responding to constant save commands from the host controller.
1) This feature was added to support users whose host controllers have very limited function-
ality. Consider the consequences of using this feature. Adding the code necessary to write
down the configuration to an SMD23E2 or SMD24E2 on power up or network connection
is fairly straight forward on most PLC based hosts. Adding this code allows you to easily
change the configuration in the host and easily configure a new drive if you ever need to
swap one out on the machine.
2) The endurance of the flash memory is a minimum of 10,000 write cycles.
Bit 9:
Binary_Input_Format –
Set to “0” to have the Motor Position, Encoder Position, and Trapped
Encoder Position reported in the multi-word format. Set to “1” to have the Motor Position, Encoder
Position, and Trapped Encoder Position reported in signed 32-bit integer format. When this parame-
ter is set to “1”, the Binary_Endian parameter in bit 7 sets the word order of the 32-bit value. See
found on page 62 for examples of the different formats.
Bit 8:
Binary_Output_Format –
Set to “0” to program the multi-word parameters in the multi-word for-
mat. Set to “1” to program the multi-word parameters in signed 32-bit integer format. When this
parameter is set to “1”, the Binary_Endian parameter in bit 7 sets the word order of the 32-bit value.
See
found on page 62 for examples of the different formats.
Bit 7:
Binary_Endian –
Only used when bits 8 and/or 9 above are set to “1”, set to “0” to the 32-bit values
in little endian format. Set to “1” to program the 32-bit values in big endian format. Siemens proces-
sors typically use big endian format, but you should refer to your PLC’s documentation to verify the
format used by your processor. See
found on page 62 for examples
of the different formats.
Bits 6 - 2: Reserved –
Must equal zero.
Configuration Word 1
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0/
1
RESERVED: Bit must equal zero.
R
eadCo
nf
ig
Sa
ve
C
on
fig
Bi
nI
nFr
m
t
Bi
nO
ut
Fr
m
t
Dat
aE
ndian
Содержание SMD23E2 Series
Страница 10: ...ABOUT THIS MANUAL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 44: ...MOTION CONTROL SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Страница 54: ...CALCULATING MOVE PROFILES SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Страница 68: ...CONFIGURATION MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 68 Notes...
Страница 88: ...COMMAND MODE DATA FORMAT SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 124: ...ETHERNET IP EXPLICIT MESSAGING SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 124 Notes...
Страница 128: ...MODBUS TCP CONFIGURATION SMD23E2 and SMD24E2 User Manual ADVANCED MICRO CONTROLS INC 128 Notes...
Страница 134: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...