Technical Information
68
Precision Induction Heating
A
MBRELL
®
Doc#801-9526-00.doc
Equipment input (440V models)
Model
3542
4048
5060
7590
8310
units
AC Line Power
5.2
5.9
7.4
11.2
12.4
kVA
AC Line Protection
15
15
15
25
25
A
Frequency 50/60
Hz
AC Line Voltage
1
370 - 440 or 440 - 520
Vac, 3
1) Level determined by model; range factory set per order; field selectable; see §3.6 for instructions
Customer
input
Port
Active
Description
Limits
Remote Input
analog
0 – 10 Vdc (Zin = 21k
)
4-20mA (Zin = 250
)
see §3
Start
closed
provide isolated contact closure*
Stop open
FLS
closed
opened contact =
Fault
19Vdc@ 0.1A
E-Stop
open
opened contact = stop
*) contacts rated for 24Vdc min, required wetting current 3mA
Customer
output
Port
Active
Description
Limits
Ready
closed
isolated solid-state output, non-polarized
24Vdc @ 1A
Heat On
closed
Fault closed
24V dc
ground referenced
24V
2% @1A
Aux Port
0-20 mA or 4-20 mA*
Serial Port
RS485
* = For more information, see “Auxiliary Output Modes and Scaling Examples”.
Electrical installations must be made by qualified personnel and must conform to applicable
safety codes.
Do not connect 440V models to 230V mains; damage and hazard will result!
Содержание 3542
Страница 16: ......
Страница 37: ...How Your EASYHEAT Works 37 AMBRELL 801 9526 00 doc Precision Induction Heating...
Страница 38: ......
Страница 73: ...Technical Information 73 AMBRELL 801 9526 00 doc Precision Induction Heating...
Страница 74: ......
Страница 75: ...7 7 T Th he eo or ry y o of f C Co oi il l D De es si ig gn n remove this page and replace with 801 9038...