Technical Information
52
Precision Induction Heating
A
MBRELL
®
Doc#801-9526-00.doc
slcdata none
Continuous 2 line response. Same as cdata without a line
feed. Terminal window will not scroll. The rate at which the
response is sent is based on the CTIME command. See ctime
for description.
1,slcdata
slcrdata none
Continuous comma delimited raw data using the same format
as rdata. Will not scroll. The line feed is removed
1,slcrdata
slctemp none
Returns single line of temperature including heat sink and air
data will not scroll and requires heat on for data to be
returned.
1,slctemp
start-
1button
none
Selects start type to be 1 button mode. Heat will remain on as
long as start signal is present. Heat will turn off when start
signal is removed.
1,start-1button
start-
2button
none
Selects 2 button start type. Heat will turn on when start signal
is pulsed. Requires stop signal pulse or button press to turn
heat off.
1,start-2button
start-fpan
none Selects start from location to be front panel.
1,start-fpan
start-rpan
none Selects start from location to be rear panel.
1,start-rpan
start-rs485 none
Selects
start
from
location to be RS485.
1,start-rs485
stat
none Provides present system status messages
1,stat
temp none
Responds with heat sink and internal temperature of the
power supply.
1,temp
temp-c
none Selects temperature to be displayed in degrees Celsius.
1,temp-c
temp-f
none Selects temperature to be displayed in degrees Fahrenheit.
1,temp-f
timer
#.##
Example sets the power supply timer to 10.20 seconds. The
variable can be 0.00 to 99999.99 a maximum of 2 places after
the decimal point is required.
1,timer,20.4
txoff none
Disables the RS485 transmitter continuous on mode as
described in the txon command above. Only needs to be used
if the user has the system in the TXON mode. (ADDED V5.02
display firmware).
1,txoff
txon none
Turns the EKOHEAT RS485 transmitter on continuously.
Normally the transmitter is disabled after a transmission, this
command will cause the transmitter to remain in the transmit
state all the time. This will aid with noise problems that can be
caused while the RF is on and the RS485 cable is picking up
random noise characters. NOTE: This command may only be
used when a single power supply is connected via the RS485
converter and must be initiated each timer the system is
powered on. (ADDED V5.02 display firmware)
1,txon
bold:
indicates valid broadcast commands (address=0); all units will respond (Ex: 0.hoff)
Содержание 3542
Страница 16: ......
Страница 37: ...How Your EASYHEAT Works 37 AMBRELL 801 9526 00 doc Precision Induction Heating...
Страница 38: ......
Страница 73: ...Technical Information 73 AMBRELL 801 9526 00 doc Precision Induction Heating...
Страница 74: ......
Страница 75: ...7 7 T Th he eo or ry y o of f C Co oi il l D De es si ig gn n remove this page and replace with 801 9038...