Touch Screen Transmitter Manual Timer Instructions
Page:
20300538
n
Safety Features
1. Low Battery Detection
When low battery condition occurs, the transmitter will turn off the fireplace.
A) Battery voltage is checked every one minute. When the battery voltage is low, the LCD displays a low bat-
tery icon which will exist in all modes.
B) The transmitter will not operate with low battery voltage. Change the batteries before the batteries become
too weak for normal operations.
2. Power On Initialization
After the power-on initialization, the transmitter sends a signal to turn off the fireplace.
3. Thermal Shutdown
When the ambient temperature is more than 99°F, the transmitter will turn off the fireplace.
A) The LCD will display “HI”.
B) The Transmitter will not function until the room temperature has dropped below 99 degree Fahrenheit.
4. Low Temperature Condition
When the ambient temperature is less than 40 degrees Fahrenheit, the LCD will display “LO”, and NO SIGNAL will
be sent to turn on the appliance.
A ll functions still remain the same for both Manual Mode and Timer Mode
5.Child-proof Protection
The child-proof icon will be shown when the child-proof mode is activated by pressing the ON button and
the OFF button at the same time for three seconds.
A) Enter childproof mode by pressing and holding both the ON button and the OFF button simultaneously
for 3 seconds. The Childproof indicator will be shown on the LCD.
B) Deactivate childproof mode by pressing and holding the ON button and the OFF button simultaneously
for 3 seconds again. The Childproof indicator disappears on the LCD.
C) The transmitter can not be operated in childproof mode.
FP2612
low battery
FP2613
HI
FP2614
lo no child
TROUBLESHOOTING
Symptom
Causes
Action
1. Battery icon on LCD on transmitter
1. Low Battery
1. Replace batteries. Change batteries
every 6 months.
2. LCD display is blank
2. Check battery installation or replace
batteries.
3. LCD display shows “funny” display
3. Reset the transmitter (see “Resetting
the Transmitter” section).
4. Appliance does not come on
2. The transmitter did not match
1. Make sure the transmitter has
with the receiver
learned to the receiver.
3. Transmitter measures temp-
1. Move transmitter to a cooler place
erature exceeding 99 degrees
and wait until temperature drops
Fahrenheit and shows “HI” on
below 99 degrees.
LCD
4. Distance between the transmitter
1. Make sure the opening distance is
and receiver is more than 30 feet
less than 30 feet.
5. Receiver not turned on.
1. Set receiver to R/S.
6. Wiring loose or no correct.
1. Check wire connection (TH/TP/TH).
f i r e - p a r t s . c o m