az 

  

  

 

 

 

 

 

EasySet 2 

Control computer 

for 

ZA-M 

ZA-V 

ZA-X 

 

 

MG6764 

BAG0217.9 06.22 

Printed in Germany 

 

 

Please read this operating 

manual before initial operation.  

Keep it in a safe place for future 

use! 

   

en 

 

 

 

Содержание EasySet 2

Страница 1: ...rating Manual az EasySet 2 Control computer for ZA M ZA V ZA X MG6764 BAG0217 9 06 22 Printed in Germany Please read this operating manual before initial operation Keep it in a safe place for future use en ...

Страница 2: ...2 EasySet 2 BAG0217 9 06 22 ...

Страница 3: ...ng the fertiliser calibration factor 8 2 5 Simulated speed distance sensor 12 2 5 1 Calibrating the distance sensor pulses per 100 m 14 2 5 2 Setting the simulated speed 15 3 Using the EasySet2 16 3 1 Spreading fertiliser 16 3 2 Performing boundary spreading 18 3 3 Spreading slug pellets and fine seeds 20 3 4 Displaying the area efficiency 21 3 5 Performing residual emptying 21 4 Connection 22 5 E...

Страница 4: ...ws the set shutter position 2 Adjustment buttons Some with LED light for showing the acti vated function 3 Buttons for control during operation Some with LED light for showing the acti vated function 4 Display with LED lights 1 2 Display Display for showing a maximum of 6 char acters LED lights above the display show the units of the displayed value ...

Страница 5: ...e sensor enter the pulses per 100 m Display of the daily output in ha Press and hold the button to reset the daily output No function The LED lights show the selected setting Changing the setting values In the active Setting menu the setting values can be changed using the marked buttons By pressing and holding the buttons the val ue changes rapidly Set values are automatically saved Go back from ...

Страница 6: ...Higher rate Higher rate on the left Higher rate on the right Reset rate to 100 Lower rate on the left Lower rate on the right Lower rate Raise limiter electrically Activate limiter Lower limiter electrically LEDs if equipped show the selected function By pressing and holding the buttons the value changes rap idly Set values are automatically saved ...

Страница 7: ...e version is shown for 2 seconds The set mode is shown for one second The Work display appears Switch off the EasySet2 STOP is shown for 2 seconds The total area efficiency is shown for 2 sec onds 2 2 Enter spread rate 1 Select the spread rate setting The spread rate is shown in kg ha 2 Enter the spread rate 3 Save the value and go back to the work display ...

Страница 8: ...iser to be spread In turn the fertiliser flow characteristics depend on fertiliser storage storage time and climatic factors working conditions The fertiliser calibration factor can be found in the setting chart for each fertiliser Use the fertiliser calibration factor from the setting chart as a base value before calibration The value of the setting chart is optimised by calibrating the fertilise...

Страница 9: ...Prepare for fertiliser calibration using the left shutter refer to the implement operating manual 2 Arbeitsbreite und Ausbringmenge eingeben 3 Select calibration 4 Enter the calibration value as a base value 5 Press and hold the button for 6 seconds The calibration routine starts 6 Open the left shutter The calibration time is shown 3 Close the left shutter as soon as enough spreading material has...

Страница 10: ...er quantity 9 Overwrite the theoretical fertiliser quantity with the collected fertiliser quantity 10 Terminate the calibration The new calibration factor will be displayed By switching off the device the calibration will be discarded 11 Save the value and go back to the work display ...

Страница 11: ...quired time in the calculation formula and calculate the calibration factor Enter the calibration factor 3 Select calibration The calibration factor will be displayed 4 Set the calibration factor 5 Save the value and go back to the work display Formula to calculate the calibration factor ZA M Calibration factor 2 2 x Collected fertiliser quantity kg Time s ZA V Calibration factor 0 65 x Collected ...

Страница 12: ... Pulses per 100 m display Possible values from 250 to 350 Display of the simulated speed Possible values from 2 to 30 km h Switching from the distance sensor to the speed simulator Shutter must be closed 1 Press until the distance sensor display reaches 250 pulses 2 Press until the display changes from 250 pulses to 12 km h The desired speed can now be entered Speed simulator active Speed proporti...

Страница 13: ... simulator to the distance sensor Shutter must be closed 1 Press until the speed simulator display reaches 30 km h 2 Press until the display changes from 30 km h to 250 pulses The pulses per 100 m can now be entered Speed proportional metering active Speed simulator not active ...

Страница 14: ...ibration run before initial operation when using a different tractor or after changing the tractor tyre size if there are differences between the measured and actual for ward speed distance travelled if there are differences between the measured and actual worked area if there are different soil conditions The Pulses per 100 m calibration value must be determined under the prevailing operating con...

Страница 15: ...lue for the pulses per 100 m is displayed The display flashes 7 Confirm the value and go back to the work display 2 5 2 Setting the simulated speed Selecting a simulated speed enables working with the implement without a speed signal distance sensor pulses per 100 m The forward speed must correspond to the simulated speed during operation Otherwise the correct spread rate will not be achieved 1 Se...

Страница 16: ...and simultaneously open the shutters For spreading on one side select the corresponding shutter The LED shows which shutter is open on one side After pressing the button you must start driving within 6 seconds SPEED display Then error message E50 appears Press the button again The shutters are closed when the speed is lower than 1 5 km h When the implement accelerates within 6 seconds the shutters...

Страница 17: ...ht Work display while driving when the spread rate is changed on one side or both sides The spread rate in kg ha is shown separate ly for both shutters If the deviation from the setpoint is greater than 5 the work display alternately shows the current value and error message E11 Wedge shaped field spreading The multi stage one sided rate change can also be used as manual part width section control...

Страница 18: ... the value for the reduction of the shutter position from the setting chart 1 Before boundary spreading ditch spreading reduce the rate on the boundary side 2 Activate the limiter for boundary spreading The LED shows the activated limiter Brief display of the limiter position 1 100 Display ON for 5 seconds after opening the shutter Then it switches back to the Work display If the shutters are open...

Страница 19: ...ter boundary spreading 1 Deactivate the limiter The LED is turned off 2 If necessary set the rate on the boundary side back to 100 Hydraulically operated limiter with position sensor Depending on the boundary spreading method the spread rate must be reduced on the boundary side Read the value for the reduction of the shutter position from the setting chart 1 Before boundary spreading ditch spreadi...

Страница 20: ...lug pellets and fine seeds Enter the values for the spread rate in kg ha and the working width before operation Determine the calibration factor for slug pellets or fine seeds see page 9 Set and maintain the simulated speed see page 12 1 Switch on the implement and the work display will be shown 2 Set the simulated speed 3 When the spreading discs are driven start driving and simultaneously open t...

Страница 21: ... reset the daily counter Total area efficiency The total area efficiency in ha is shown for 2 seconds after switching off and cannot be reset 3 5 Performing residual emptying 1 Press and hold the button for 6 seconds The emptying function starts the display flashes 2 Open the left right shutter for residual emptying The display is continuously illuminated 3 Close the left right shutter after resid...

Страница 22: ...d spread rate con trol Mode 4 5 the connection cable for the speed signal pul 100m must be con nected to the signal socket or to a wheel sensor 3 Equipment for installing the EasySet in the tractor cab 4 Implement plug to connect the implement to the EasySet Store the control computer in a dry place when you remove it from the tractor cab ...

Страница 23: ...d and press at the same time and hold until the display briefly shows ConfF Modes are shown flashing LED flashes 2 Select implement mode 1 0 Delivery status spare part 1 ZA M 2 ZA V 3 ZA X 3 Save implement mode 4 Select boundary spreading device mode 2 00 No boundary spreading 01 Hydraulically operated limiter with po sition sensor 02 Electrically operated limiter 5 Save boundary spreading device ...

Страница 24: ... left and right To do so remove the locking clip 2 pull out the pin 3 and remove the sleeves 4 2 Open shutter For this purpose slide both motors slightly to the rear 3 Remove the maintenance flaps on the left and right 4 Insert the round steel 2 through the right maintenance flap vertically relative to the shutter 1 into the right shutter opening and hold it tight The round steel must touch the sh...

Страница 25: ...sert the round steel 2 through the right maintenance flap vertically relative to the shutter 1 into the left shutter opening and hold it tight The round steel must touch the shutter o pening 4 and must not rest on the bottom plate 3 9 Close the left shutter manually until the shutter touches the round steel To do so pull the left motor back towards the front 10 Confirm the calibration of the left ...

Страница 26: ...ing the motor 4 Perform work steps 1 3 on both sides EasySet is switched off 5 Press the Power on rate left and right buttons simultaneously and hold for 3 se conds ConF and the current calibration value appear briefly consecutively The shutter LEDs are flashing The voltage values in volts for the left and right shutters are shown 6 Confirm the calibration of the left shutter 7 Confirm the calibra...

Страница 27: ...ing the motor 4 Perform work steps 1 3 on both sides EasySet is switched off 5 Press the Power on rate left and right buttons simultaneously and hold for 3 se conds ConF and the current calibration value appear briefly consecutively The shutter LEDs are flashing The voltage values in volts for the left and right shutters are shown 6 Confirm the calibration of the left shutter 7 Confirm the calibra...

Страница 28: ... s ACTUAL value Adjust forward speed E20 Warning The calibration value is outside of the pre scribed limits 0 s Display on the left E20 On the right calculated value Repeat calibration E32 Warning Boundary spreading setting motor is not responding 2 s The output of the boundary spread ing system must be switched off Check motor E39 Warning Angle sensor of the left shutter has failed 0 s Check the ...

Страница 29: ...see page 12 2 Open and close the shutter through the Emptying menu see page 21 WARNING Risk of crushing fingers in the elec trically actuated shutters There may not be anybody else work ing on the shutters when they are opened and closed 3 Before working on the bottom group switch off the control computer ...

Страница 30: ...right shutter Target rate on both sides higher lower 100 Target rate Working width Calibrate hold for 6 seconds Calibrate distance sensor Simulated speed Target rate on the left higher lower Target rate on the right higher lower On Off 1 Area efficiency 2 6 seconds area 0 Activate deactivate limiter 1 Limiter tilt 2 Change the setting values ...