Preparing the EasySet2
EasySet 2 BAG0217.9 06.22
15
Determining the pulses per 100 m
1. Measure a calibration distance of exactly
100 m.
2. Mark the start and end points.
3. Drive up to the starting point.
4.
Press and hold the button for 6
seconds.
→
The display flashes.
5. Drive the calibration distance of exactly 100
m.
→
The pulses are being counted.
6. Stop.
→
The determined value for the pulses per
100 m is displayed.
→
The display flashes.
7.
Confirm the value and go back to
the work display.
2.5.2
Setting the simulated speed.
Selecting a simulated speed enables working with the implement
without a speed signal (distance sensor / pulses per 100 m).
The forward speed must correspond to the simulated speed during
operation. Otherwise, the correct spread rate will not be achieved.
1.
Select the simulated speed.
If the distance sensor display (values greater
than 250) first switches to simulated speed, see
page 12.
2.
,
Enter the value for the
simulated speed.