6.2.5 Hardware Menu
Enter Password
: Enter a password here to unlock the unit (only needed if the
unit has been previously locked using the option “Hardware>Lock Unit”).
Configure
:
o
Change password
: change the factory default password. The new
password may have up to 8 characters. You will be first asked for the
old password.
NOTE
: The factory default password is “Password” (case sensitive)
o
Network Settings
: allows to manually configure the IP of the device
(static IP).
o
Power On Preset
: Set here the preset that will be selected at startup.
The default setting is “last setting”.
o
Global Access Rights
: select which controls will be unlocked even the
“Lock Unit” control is selected. Click on the checkbox of the functions
that should be available to the user without entering a password:
o
Output mode
: pre-select the input assignment to outputs, in groups of
two (Dual Bridge or Mono).
o
Routing
: Changes the input assignments and links of outputs as
described in Section 5.3.5.
o
AES -> Analog Failover
: when this feature is On, and the unit is
operating with AES input, the processor will automatically switch to the
analog input if the AES signal is lost. A valid analog input must be
connected to the desired inputs.
Lock unit
:
In order to lock the unit by password, select “Hardware > Lock
Unit”. To unlock the unit again, select “Hardware > Enter Password”.
Go to Standby:
the DSP will go into standby mode (low power consumption).
In this mode, there is no output signal. Is is equivalent to press on the
Standby button at the Device List.
Set Pin
: Set a 4-digit pin to allow the access to the unit via software. If the
PIN needs to be removed, select this function and leave the PIN field blank
(t
he message “Invalid PIN” will be shown). If the PIN is forgotten, a firmware
upgrade is needed (see Chapter 8).