background image

Preface

Target Audience

The target audience for this guide is the user who has taken delivery of a packaged Amaranten F

18

00

Series appliance. The guide takes the user from unpacking and installation of the device through to
power-up and initial network connection.

Text Structure

The text is divided into chapters and subsections. Numbered subsections are shown in the table of
contents at the beginning of the document.

Text links

Where a "See section" link is provided in the main text, this can be clicked on to take the reader dir-
ectly to that reference eg. see Chapter 7, Hardware Specifications.

Web links

Web links included in the document are clickable eg. http://www.amaranten.com

Notes to the main text

Special sections of text which the reader should pay special attention to are indicated by icons on the
the left hand side of the page followed by a short paragraph in italicized text. There are the follow-
ing types of such sections:

Note

This indicates some piece of information that is an addition to the preceding text. It
may concern something that is being emphasised or something that is not obvious or
explicitly stated in the preceding text.

Tip

This indicates a piece of non-critical information that is useful to know in certain situ-
ations but is not essential reading.

Caution

This indicates where the reader should be careful with their actions as an undesirable
situation may result if care is not exercised.

Important

This is an essential point that the reader should read and understand.

Warning

This is essential reading for the user as they should be aware that a serious situation
may result if certain actions are taken or not taken.

vi

Содержание F1800 Series

Страница 1: ...and Setup guide Amaranten F1800 Series Amaranten Corporation Ltd 9M Oriental Kenzo Mansion 48 Dongzhimenwai Avenue Dongcheng District 100027 Beijing China http www amaranten com Published 2006 09 21 C...

Страница 2: ...nufacturer reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of the manufacturer to notify any person of such revision or cha...

Страница 3: ......

Страница 4: ...Connecting Power 8 3 Initial Setup 12 3 1 Attaching Connectors 12 3 1 1 Connecting to a Network 12 3 1 2 Connecting the Console Port 12 3 2 Setup with local RS232 console 14 3 3 Setup with Display and...

Страница 5: ...the Amaranten F1800 Series 8 3 1 A typical installation setup 12 4 1 Replaceable modules in an F1800 Series device 19 4 2 Replacing a F1800 Series power supply 20 4 3 An F1800 Series AC power supply...

Страница 6: ...which the reader should pay special attention to are indicated by icons on the the left hand side of the page followed by a short paragraph in italicized text There are the follow ing types of such s...

Страница 7: ...es Appliance 2 A mounting kit for 19 racks The side brackets for this kit are already be attached but can be removed for flat surface operation 3 Attachable rubber feet for flat surface mounting 4 1 x...

Страница 8: ...net ports with logical interface names fe1 to fe4 These connections are also capable of link speed auto negotiation and can operate with 10Base T or 100Base Tx Port Status LEDs On the F1800 Series the...

Страница 9: ...Port Status LEDs Chapter 1 Product Overview 3...

Страница 10: ...circuit The maximum ampere ratings are usually printed on the devices near the AC power connectors Do not install the appliance in an environment where the operating ambient temperature might exceed t...

Страница 11: ...mounted as low as possible with the heaviest devices at the bottom and progressively lighter devices installed above Note F1800 Series devices come with rack mounting brackets already attached to the...

Страница 12: ...ese must be purchased seperately Installation of SFP units is usually simlar With the units shown the modules are inserted into sock ets with the label facing upwards The module slides gently into pos...

Страница 13: ...Figure 2 4 Installing a 1000 Base TX module 2 2 Installing SFP modules Chapter 2 Installation 7...

Страница 14: ...is properly connected then a power supply failure will be assumed and a high pitched continuous alarm will sound when the Amaranten Security Gateway is switched on For more details on power supply fa...

Страница 15: ...d for instance to the rack cabinet in which the F1800 Series is installed Connect cables to the power supply Be certain that the voltage from all DC power source cables is 0V before and during install...

Страница 16: ...Connecting DC Power Chapter 2 Installation 10...

Страница 17: ...Connecting DC Power Chapter 2 Installation 11...

Страница 18: ...he network using a regular straight through Ethernet cable In the diagram below the Amaranten appliance unit top left is connected to a switch bottom left Figure 3 1 A typical installation setup The F...

Страница 19: ...iate connectors The F1800 Series package includes an RS 232 null modem cable To connect a terminal to the console port follow these steps 1 Set the terminal protocol as described previously 2 Connect...

Страница 20: ...terminal window When the device is starting a text similar to the following will appear in the terminal window 2 Select the interface that you have chosen for communication with the management station...

Страница 21: ...face 4 The following will appear in the terminal window Press Y to start CorePlus 5 You will the receive a confirmation message that CorePlus has successfully started as shown below 3 2 Setup with loc...

Страница 22: ...Select Interface 3 Now enter the IP address that is to be used for management purposes To do this press Left un til you get to the IP Address menu Press Down once to get to the IP address configura ti...

Страница 23: ...ty Gateways This describes how to register your Amaranten li cense and set up a first security policy Amaranten CorePlus Adminis trators Guide This describes the general operation and control of the C...

Страница 24: ...3 4 Finalizing the Configuration Chapter 3 Initial Setup 18...

Страница 25: ...pply In the event of a single power supply failure a high pitched continuous sound will be heard coming from the F1800 Series device In normal operation there is a green LED light that is visible on t...

Страница 26: ...ching off the Alarm The high pitch alarm indicating power supply failure is deliberately intrusive To switch it off press in the small red switch which is recessed into the F1800 Series cas ing This i...

Страница 27: ...Figure 4 4 An F1800 Series DC power supply unit Hot swapping power supplies Chapter 4 Product Maintenance 21...

Страница 28: ...ed use it is nonetheless a recommended precaution that the fan module shown below be replaced every two years Figure 4 5 An F1800 Series fan module Replacement Steps Power off the F1800 Series device...

Страница 29: ...Replacement Steps Chapter 4 Product Maintenance 23...

Страница 30: ...ion then at the time of requesting the RMA number the Purchaser may also pro pose special procedures as may be suitable to the case After an RMA number is issued the defective product must be packaged...

Страница 31: ...ln avl gnas till dess att skyddsjorden har terst llts F r LAN kablage g ller dessutom att om LAN et t cker ett omr de som betj nas av mer n ett str mf rs rjningssystem m ste deras respektive skyddsjor...

Страница 32: ...Considerazioni sulla sicurezza Questo prodotte omologato nella classe di sicurezza I ed ha un terminale protettivo di collega mento a terra Dev essere installato un collegamento a terra di sicurezza...

Страница 33: ...de la LAN se vean sometidos de vez en cuando a voltajes moment neos que entra en peligro rayos o alteraciones en la red de energ a el ctrica Manejar con precauci n los componentes de metal de la LAN...

Страница 34: ...Yes Redundant Hot Swappable Power Supply AC 100 240V 50 to 60 Hz AC Redundant Hot Swappable Power Supply DC 36VDC to 72VDC Figure 7 2 Regulatory and Safety Standards Safety UL CE EMC FCC class A CE cl...

Отзывы: