February 1998
5
12074208
Component Specifications
C om ponent
D escription
Test Procedures
A3079001
Bulb
Volt
W att
115 VAC
40 watts
C 8931604
C apacitor, com pressor run
Volt
C apacitance
220 VAC
15 Mfd +10%
-5%
12049702
C om pressor
Type
BTUH
Volt
W att
C urrent
Lock rotor
Full load
R esistance
R un W indings
Start W indings
Fan C ooled, R 134a refrigerant
970 BTU H
115 VAC 60 H z
176 w atts
21.3 A
1.6 A
2.60
Ω
4.35
Ω
B2150504
D rier
D rier m ust be changed every tim e the system is opened for testing or
com pressor replacem ent.
D esiccant (20) 8 x 12 4AXH - 7 M.S. -G ram s
10428411
H eater, evaporator
Volt
W attage
R esistance
115 VAC
450 ± 5% W
30 ± 5%
Ω
Volt
W attage
R esistance
115 VAC
20 W
661 ±7.5
Ω
12401301
H eater, m ullion
For service use only.
Foam ed in place. N ot powered from
the factory.
To avoid risk of electrical shock w hich can cause death or
severe injury, disconnect electric al power to unit before
servicing.
To connect m ullion heater to pow er:
1.
D isconnect power to unit using pow er switch.
2.
R em ove toe grille. Locate water valve w iring harness.
3.
C arefully, slit wiring harness vinyl sleeve to expose one black and
one white lead bent with bullet te rm inators.
4.
Locate m ullion heater leads at the left side of cabinet and connect to
black and white leads.
5.
W rap vinyl sleeve with electrical tape to close slit.
12106801
H igh voltage circuit board, PC
See "Electronic Functional
D escription"
12067101
Low voltage circuit board, PC
See "Electronic Functional
Testing"
WARNING
!