35
RS1300005 Rev. 0
Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
G
R I LLE
G
R I L LE
S
U M P
F
A C A D
S
C R E W S
Dispenser Ice Chute Door
1. Remove dispenser facade (see dispenser facade
removal)
2. Remove ice chute assembly (see D/C solenoid
removal)
3. After ice chute assembly is removed unsnap ice
chute dispenser door from assembly.
4. Retain spring if good, replace if bad.
5. Remove rubber seal from door and replace if bad.
6. Reverse procedure to reassemble.
DC
S
OLENOID
L
IGHT
S
OCKET
I
CE
C
HU TE
D
OOR
I
CE
C
HU TE
D
OOR
H
INGE
I
CE
C
HU TE
A
SSEMBLY
Dispenser Light Socket
1. Remove dispenser facade (see dispenser facade
removal)
2. Remove light bulb.
3. Disconnect wires to socket assembly.
4. Squeeze tabs located by terminals to release socket.
5. Reverse procedure to reassemble.
Dispenser D/C Solenoid
1. Remove dispenser facade (see dispenser facade
removal)
2. Remove dispenser water tube clip.
3. Remove water tube from assembly collar.
4. Remove wires from dispenser light socket.
5. Disconnect ground wire from solenoid assembly.
6. Disconnect wires from D/C solenoid.
7. Remove screws holding D/C solenoid and ice chute
assembly.
8. Remove complete assembly.
9. Rotate to backside and remove screws holding D/C
solenoid to ice chute assembly.
10. Lift ice chute door to release plunger from retainer.
11. Slide D/C solenoid out of the side of ice chute
assembly.
12. Reverse procedure to reassemble.
Dispenser Water Tube
1. Remove toe grill and left hinge cap to expose
dispenser water line coupler.
2. Disconnect water line coupler.
3. Remove compression nut and sleeve from door side
of coupler.
4. Remove dispenser facade (see dispenser facade
removal).
5. Remove holding clip from water line in cavity.
6. Pull water tube up from conduit in cavity to remove
water tube.
7. Reverse procedure to reassemble.
High Voltage Board (Messenger Model)
1. Remove dispenser facade (see dispenser facade
removal)
2. Disconnect high voltage and low voltage harness
from high voltage board mounted on back wall of
cavity.
3. Remove screws holding high voltage board to cavity.
4. Reverse procedure to reassemble.
Содержание 22 Cu. Ft