RS1300005 Rev. 0
32
Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Auger Motor Capacitor
1. Remove auger ice bucket and fast freeze shelf.
2. Remove auger motor assembly. (see auger motor
assembly removal.
3. Disconnect leads from capacitor, remove hex screw
and remove capacitor.
4. Reverse procedure to reassemble.
Evaporator Fan Motor Assembly
1. Remove all freezer shelving.
2. Remove lower evaporator cover hex head screws.
3. Remove evaporator cover.
4. Disconnect evaporator fan wiring and ground from
motor.
5. Raise top freezer cover about two inches.
6. Grasp and pull complete evaporator motor assembly
toward you.
7. Remove assembly from freezer.
F
AN
B
L ADE
S
H RO U D
A
S SEMBL Y
E
VAPO RA TO R
F
AN
M
O T O R
E
VAPO R AT O R
F
AN
C
L IP
Evaporator Fan Motor and Fan Blade
1. Remove evaporator fan motor assembly (see
evaporator fan motor assembly removal).
2. Remove evaporator fan blade by pulling blade off
evaporator fan shaft.
3. Remove fan motor by squeezing motor retainer clips
together to release retainer.
4. Remove retainer and slide motor out.
5. Reverse procedure to reassemble. Evaporator fan
blade should be pushed down on on shaft until it is
seated.
Evaporator Removal
NOTE:
Reclaim refrigerant per instructions in “Service
Procedures” before attempting evaporator
removal. To avoid system contamination, do not
leave system open for more than 10 minutes.
1. Remove all freezer shelving.
2. Remove lower evaporator cover hex head screws.
3. Remove evaporator cover.
4. Remove defrost thermostat and defrost heater from
coil ( see disassembly instructions for both).
5. Release evaporator coil from clips by pulling coil off of
clips.
6. Unsweat evaporator coil after completing reclaiming
procedures found in Service Procedures section of
this manual.
7. Reverse procedure to reassemble.
Defrost Terminator (Thermostat)
1. Remove all freezer shelving.
2. Remove lower evaporator cover hex head screws.
3. Remove evaporator cover.
4. Disconnect orange lead from defrost heater.
5. Cut Brown lead close to defrost terminator.
6. Unclip defrost terminator from evaporator coil.
7. Replace terminator and use wire nut(s) included in
defrost terminator kit.
8. Reverse procedure to reassemble.
D
EF ROST
T
HERMOSTAT
D
EFRO ST
H
EAT ER
H
EAT ER
C
LIPS
Defrost Heater
1. Remove all freezer shelving..
2. Remove lower evaporator cover hex head screws..
3. Remove evaporator cover.