A
Appendix
85
ML-7 Series/ML-9001A
Appendix
A
Troubleshooting
97
Out of Memory:
Font Registration
-
Memory capacity has been reached when attempting to register the
font, the file size of font is 0, or the font may be unsupported.
Check the registration of the font (1st/2nd standard fonts, cursive
text, or kanji).
98
Out of Memory:
RAM Registration
-
Memory capacity has been reached when attempting to store a
variable number, serial number or calendar setting in RAM, or the
variable number, serial number or calendar setting may be
unsupported.
Check RAM storage.
99
Out of Memory:
Part Registration
-
Memory capacity has been reached when attempting to register a
part, the file size of part is 0, or the part may be unsupported.
Check part registration.
100
Out of Memory:
Layout Registration
-
Memory capacity has been reached when attempting to register a
layout file, the file size of layout is 0, or the layout file may be
unsupported.
Check the layout file registration.
110
Barcode:
Encoding Error
-
•
Includes unsupported characters.
•
In the case of ITF barcodes, there is an odd number of characters.
•
Grouped variable data includes special characters.
111
Barcode:
BMP Overflow
-
The figure size exceeds the limit for barcode encoding.
Divide the data.
112
2D Code Error
-
The data size exceeds the limit for 2D barcode encoding.
Divide the data.
190
192
194
LD PWM Control
Error
LD Temperature
Control Error
LD Temperature Error
(ML-7112AH)
Off
An LD temperature error has occurred.
•
Clean the control unit air filter.
•
Ensure that the temperature around the equipment is between
5 and 35
°
C.
•
Turn on the power again and wait at least 10 minutes before
starting the laser.
If the error persists following these measures, contact us.
191
193
195
Crystal PWM Control
Error
Crystal Temperature
Control Error
Crystal Temperature
Error
(ML-7112AH)
-
A crystal temperature error has occurred.
•
Clean the head unit air filter.
•
Ensure that the temperature around the equipment is between
5 and 35
°
C.
•
Turn on the power again and wait at least 10 minutes before
starting the laser.
If the error persists following these measures, contact us.
* In the event of errors other than those listed above, contact us and identify the error code.
Error
Code
Error Details
LD
Cause and Corrective Action
Содержание ML-7 Series
Страница 1: ...Installation Maintenance Z11OM1158223 20 LD Pumped Laser Marker ML 7 Series ML 9001A OPERATION MANUAL...
Страница 4: ......
Страница 8: ...4 ML 7 Series ML 9001A Contents...
Страница 43: ...Chapter 4 39 ML 7 Series ML 9001A 4 3 Air Filter Inspection and Replacement 5 Attach the air filter cover...
Страница 82: ...Chapter 4 78 ML 7 Series ML 9001A Chapter 4 Maintenance...
Страница 83: ...Appendix...