Chapter
4
50
ML-7 Series/ML-9001A
Chapter
4
Maintenance
■
ML-7112AH
Have the following items ready when inspecting or replacing the FC-LD of the ML-7112AH:
•
FC-LD (new or refurbished)
•
Phillips screwdriver
1
Unscrew the six screws at the back of
the Control Unit.
2
Remove the cover on the right side by
sliding it back about 25 mm and lifting it
up.
Similarly, remove the cover on the left
side.
3
Disconnect the Peltier power supply
relay connector.
・
Before replacing the FC-LD, always turn off the equipment. Wait at least 5 minutes before
starting work. Performing replacement while the unit is on or immediately after it is turned
off poses a risk of electric shock, fire, or injury (including burns and blindness).
・
Never attempt to disassemble, repair, or modify the FC-LD yourself.
Slide the cover back
about 25 mm, then lift
it.
Control Unit, from right
Cover on right
Relay connector
for Peltier power
supply