Chapter
4
51
ML-7 Series/ML-9001A
4.5 FC-LD (Oscillation Unit) Inspection and Replacement
4
At the thermal switch, disconnect the
relay connectors for the CN5 thermal
switch, LD power supply, and relay.
Before disconnection, remove each
clamp.
5
Unplug the signal line connector,
keeping it level as you pull it out.
6
To remove the optical fiber, loosen the
optical fiber fixture at the back of the
Control Unit.
7
Remove the clamp securing the optical
fiber.
Relay connector
CN5 thermal switch relay connector
LD power
supply relay
connector
Signal line
connector
Optical fiber fixture
Clamp