Operation and Administration
5-11
♦
Set Complete Operators Defaults:
Available only with Administrator
access rights. Resets the unit to the Operator Defaults configuration,
excluding the Administrator Password.
♦
Set Partial Factory defaults:
Resets the unit to the Operator Defaults
configuration, excluding the parameters that are required to maintain
connectivity and management access. These parameters are listed in
Table 5-2.
Save Current Configuration As Operator Defaults
The Save Current Configuration As Operator Defaults option is available
only under Administrator access rights. It enables defining the current
configuration of the unit as the Operator Defaults configuration.
Change Unit Name
The Change Unit Name option enables changing the name of the unit,
which is also the system’s name in the MIB2. The name of the unit is also
used as the prompt at the bottom of each Monitor window.
Valid values: A string of up to 32 printable ASCII characters.
The default unit name is an empty string.
Change Password
The Change Password submenu enables changing the access password(s).
A user with Installer access rights can view and change the passwords for
Read Only and Installer levels. A user with Administrator access rights can
view and change the passwords for all levels.
Valid values: A string of up to 8 printable ASCII characters
Refer to Working with the Monitor Program on page 5-2 for a list of the
default passwords for each of the access levels.
Flash Memory Control
The Flash Memory Control submenu enables selecting the active software
version for the unit.
The flash memory can store two software versions. One version is called
Main and the other is called Shadow. New software versions are loaded as
the shadow version. You can select the shadow version as the new active
version by selecting
Reset and Boot from Shadow Version
. However,
after the next reset, the main version is re-activated. To continue using the
currently active version after the next reset, select
Use Current Version
After Reset
:
The previous shadow version will be the new main version,
and vice versa.
Содержание BreezeACCESS VL 5.4
Страница 1: ...BreezeACCESS VL System Manual January 2003 SW Version 1 0 Cat No 213409 ...
Страница 12: ......
Страница 30: ......
Страница 60: ......
Страница 117: ...Operation and Administration 5 57 The available values range from 1 100 The default value is 3 ...
Страница 124: ...BreezeACCESS VL System Manual B 2 ...
Страница 126: ...BreezeACCESS VL System Manual C 2 ...
Страница 137: ...Supported MIBs and Traps D 11 Air Interface Parameters ...
Страница 147: ...Supported MIBs and Traps D 21 ...
Страница 148: ......