Continuous Link Quality Display (SU only)
The
Continuous Link Quality Display
option displays continuously
updated information regarding the quality of the received signal using
Signal to Noise Ratio (SNR) measurements.
Click any key to abort the test.
MAC Address Database
MAC Address Database in AU
The
MAC Address Database
option in the AU displays information
regarding the Subscriber Units associated with the AU as well as bridging
(forwarding) information. The following options are available
:
♦
Display Bridging and Association Info:
The Display Bridging and
Association Info option displays a list of all the Subscriber Units and
stations in the AU’s Forwarding Database.
For stations behind an SU,
the SU’s MAC address is also displayed (SU Address).
Each MAC address entry is followed by a description, which may
include the following
:
Et (Ethernet):
An address learned from the Ethernet port.
Vp (Virtual port):
An address of a node behind an associated SU.
For these addresses, learned from the wireless port, the address of
the applicable SU is also displayed (in parenthesis).
St (Static):
An associated SU. For these entries, the SW version of
the SU is also displayed.
Sp (Special):
5 addresses that are always present, which include:
♦
The MAC address of the AU, which appears twice as it is
learned from both the Ethernet and wireless ports.
♦
Alvarion’s Multicast address (01
:
20
:
D6
:
00
:
00
:
01, which also
appears twice. The system treats this address as a Broadcast
address.
♦
The Ethernet Broadcast address (FF-FF-FF-FF-FF-FF).
In addition, a summary table displays information about the
Forwarding Database (Bridging Info) and the Associated Subscriber
Units Database (Association Info). Each database includes the
following information
:
The current number of entries. For Bridging Info this includes the
Et
(Ethernet) and the
Vp
(Virtual ports) entries. For Association Info
this is the number of currently associated SUs.
Содержание BreezeACCESS VL 5.4
Страница 1: ...BreezeACCESS VL System Manual January 2003 SW Version 1 0 Cat No 213409 ...
Страница 12: ......
Страница 30: ......
Страница 60: ......
Страница 117: ...Operation and Administration 5 57 The available values range from 1 100 The default value is 3 ...
Страница 124: ...BreezeACCESS VL System Manual B 2 ...
Страница 126: ...BreezeACCESS VL System Manual C 2 ...
Страница 137: ...Supported MIBs and Traps D 11 Air Interface Parameters ...
Страница 147: ...Supported MIBs and Traps D 21 ...
Страница 148: ......