Installation
3-9
Figure 3-4: The Waterproof Seal
8.
Route a straight, uncrimped Cat. 5 Ethernet cable (8-wire, 24 AWG)
through both the top nut and the waterproof seal.
NOTE:
The 8-wire cable should be shielded.
9.
Insert and crimp the RJ-45 connector. Refer to Appendix A for
instructions on preparing the cable.
10.
Connect the Ethernet cable to the outdoor unit RJ-45 connector.
11.
Replace the waterproof seal and then the top nut. Make sure that the
external jack of the cable is well inside the waterproof seal to
guarantee a good seal.
12.
Route the cable to the location selected for the indoor equipment.
13.
Assemble an RJ-45 connector with a protective cover on the indoor
side of the indoor-to-outdoor cable.
Installing the SU-NI/AU-NI
Indoor Unit
1.
The unit can be placed on a desktop or a shelf. Alternatively, it may be
wall-mounted. The drilling template included with the unit can be
used to simplify the wall installation process.
2.
Connect the Indoor-to-Outdoor cable to the RADIO connector, located
on the front panel of the indoor unit shown in Figure 3-5 on page 3-
10.
Содержание BreezeACCESS VL 5.4
Страница 1: ...BreezeACCESS VL System Manual January 2003 SW Version 1 0 Cat No 213409 ...
Страница 12: ......
Страница 30: ......
Страница 60: ......
Страница 117: ...Operation and Administration 5 57 The available values range from 1 100 The default value is 3 ...
Страница 124: ...BreezeACCESS VL System Manual B 2 ...
Страница 126: ...BreezeACCESS VL System Manual C 2 ...
Страница 137: ...Supported MIBs and Traps D 11 Air Interface Parameters ...
Страница 147: ...Supported MIBs and Traps D 21 ...
Страница 148: ......