Chapter 2 - Installation
Installing the Universal IDU Indoor Unit
BreezeACCESS EZ AU-EZ
23
System Manual
5
Connect the 10/100 BaseT ETHERNET connector to the network. The cable
connection should be a straight Ethernet if connecting the indoor unit to a
hub/switch and a crossed cable if connecting it directly to a PC Network
Interface Card (NIC).
2.4.1
RESET Button Functionality
Using a sharp object, press the recessed RESET button for a short time to reset
the unit and reboot from the Main version.
The RESET button can be used for setting the unit to its factory defaults. Press
the button for about 10 seconds (until the ETH LED of the IDU stops blinking):
the unit will reboot with the factory default configuration.
NOTE
The length of the Ethernet cable connecting the indoor unit to the user's equipment, together with
the length of the Indoor-to-Outdoor cable, should not exceed 100 meters.