TESTING AND COMMISSIONING
6.4
fACTORy RESET
The factory reset restores the settings that are set by default when the drive delivering. The con-
figured positions of the door will be deleted. The recorded remote controls will be saved.
1
Press and hold the button
for about 5 secs to enter the
programming mode
2
After the appearance of ‘
P1
’
inscription press the button
3
After the appearance of ‘
P0
’
inscription press the button
4
After the appearance of ‘
f0
’
inscription press the button
5
After the appearance of ‘
– –
’ inscription press and hold the button
for
5 secs. A dot will appear on the display, this means the resetting to default
settings
6
To exit the programming mode press the button
twice or wait for
15 secs (until automatic exit the setup menu). The display will show two dots
7.
TESTING AND COMMISSIONING
This is an important stage of drive system installation. The test is performed as follows:
• make sure that the requirements of section 1. ‘General warnings and safety rules’ and other
manual requirements are met in full.
• ensure stable and secure mounting of the drive and the guide rail.
• unblock the drive (section 4.2. ‘Manual unblocking’). Manually open and close the door
several times. Make sure that there are no points of increased resistance to motion, and
there are no assembly and adjustment defects of the doors and drive. Return to the
blocked state.
• perform the full
open-close
cycle. Make sure, that the door moves in the required
directions, the leaf of the door moves smoothly. At the end of opening and closing the
door moves slowly.
• check the guide belt / chain tension degree and tighten if necessary (
fig.
19).
• make sure that the integrated LED backlight is functioning. It is active when the door is
moving and for a set time after the door stops.
• check the correct working of the connected control devices (control buttons, remote
controls).
• check the correct working of each connected safety and alarm device (photocells,
movement stop devices, lamps etc.). Check the photocells for the absence of interaction
with other devices, to do so—close the optical axis: first close to TX photocell (transmitter),
then close to RX photocell (receiver) and then in the middle, between the two photocells.
Make sure that in all cases the drive properly reacts to the activation of photocells (during
closing the door stops and then fully opens).
• check the ability of the drive to identify the interaction with foreign objects during closing.
Put a 50 mm high obstacle on the floor. When the door contacts the obstacle during door
closing, the drive should stop the door and open completely.
Table 17