LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
|
COMMANDES LEVIGATO (SERIE LG)
29
ADjUSTMENT
MENU
SETTING
DESCRIPTION
VALUES
DEfAULT
VALUE
P7
f1
Select the operating mode of the photocells
(input ‘
PH1
’). The input is activated when opening,
or is activated when closing
CL
—is activated
when closing /
OP
—is activated
when opening
CL.
Y
Connection input ‘
PH1
’ will be active only when closing (
CL
), if automatic closing is enabled
(pause time is set in
P4
-
f1
…
f4
settings)
f3
function
‘
PHOTOTEST
’. The operation of the
photocells is checked before movement by
short-term disconnection and then reconnection
of the power to the photocells transmitter.
Photocells connection diagram—
fig.
26
no
—
Off
/
on
—
ON
no.
Y
Function ‘
PHOTOTEST
’ cannot be switched off (no) if the automatic closing is enabled (pause
time is set in
P4
-
f1
…
f4
settings)
f4
Select the operating mode of the safety
sensor
(input ‘
SE
’). The input is not activated, or
is configured for a resistive sensor (8.2 kOhm),
or is configured for an optoelectronic sensor
(optosensor / OSE)
no
—
Off
/
01
—sensor
8.2 kOhm /
02
—optosensors
no.
f5
Photocells blocking close to the floor level
and the safety sensor (input
‘
SE
’
)
. The setting
specifies the distance from the floor where the
photocells and the safety sensors are ignored
no
—
Off
/
01
,
02
,
03
…
99
99
—maximum
200 mm
no.
P8
f1
The setting of output SL / LL in signal lamp
mode SL
: continuous or flashing
no
—flashing /
on
—continuous
on.
f2
The delay time of the movement beginning
(time of the preliminary activation of the signal
lamp). During the delay time, the signal lamp (
SL
)
works, it signals the beginning of door movement
by a set number of seconds
00
,
01
…
10
00
—0
sec
,
10
—10
secs
00.
f3
Operating time in the illumination lamp
(
LL
)
mode and the drive illumination after stopping
the door movement
no
/
01
,
02
…
99
no
—after the end
of door movement it
is off (0 sec)
01
—5
secs
;
99
—500
secs
(8 min 20
secs
)
06.
(30 secs)
f4
The output mode
‘
SL/LL
’: the signal lamp (
SL
) or
the illumination lamp (
LL
).
The signal lamp (
SL
)—works when the door
movement and when the door movement is
delayed (
P8
–
f2
time setting).
The illumination lamp (
LL
)—works when the door
movement and after stopping the movement
(time setting
P8
–
f3
)
no
—signal
lamp /
on
—
illumination lamp
no.