- 14 - 

eFlow104N Series Installation Guide

eFlow Power Supply/Chargers can be

Controlled and Monitored while Reporting

Power/Diagnostics from Anywhere

over the Network...

LINQ2 Mounts Inside any eFlow Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power 

supply/chargers to help keep systems up and running at optimal 

levels. It facilitates fast and easy installation and set-up, minimizes 

system downtime, and eliminates unnecessary service calls, which 

helps reduce Total Cost of Ownership (TCO) - as well as creating a 

new source of Recurring Monthly Revenue (RMR). 

LINQ2 

Features:

-  UL Listed in the U.S. and Canada.

-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.

-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, 

  input trigger state change, output state change and unit temperature.

-  Access control and user managment: Restrict read/write, Restrict users to specific resources

-  Two (2) integral network controlled Form “C” Relays.

-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.

-  Email and Windows Dashboard notifications

-  Event log tracks history.

-  Secure Socket Layer (SSL).

-  Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Network

Connection:

Installation,

Programming

and Monitoring

L

G

N

NC

C

NO

NC

C

NO

BA

T F

AIL

AC F

AIL

AC

AC1

DC

TRIGGER EO

L

SUPER

VISE

D

disable

enable

2 hr

.

1 min

.

AC DELAY   

SHUTDOWN

O N

eFlow

Power

Supply/Charger

Содержание eFlow104N Series

Страница 1: ...t 8 PTC Protected Class 2 Power Limited Outputs eFlow104N16D eFlow104NX16D 10A 24VDC Sixteen 16 PTC Protected Class 2 Power Limited Outputs eFlow104N Series Power Supply Chargers Models Include Rev 10...

Страница 2: ...104NX eFlow104N8 eFlow104NX8 eFlow104N16 and eFlow104NX16 The following units provide Class 2 power limited outputs eFlow104N8D eFlow104NX8D eFlow104N16D and eFlow104NX16D If a power limited output is...

Страница 3: ...60Hz Input Battery Wires Minimum 0 25 spacing must be provided CAUTION Do not touch exposed metal parts Shut branch circuit power before installing or servicing equipment There are no user serviceabl...

Страница 4: ...position Fig 1c pg 5 9 Trigger terminals are end of a line resistor supervised 10k ohms Opening or shorting trigger terminals will cause DC output to shutdown Fig 1d pg 5 10 Place a jumper for non lat...

Страница 5: ...power is present Contact rating 1A 30VDC A removed battery is reported within 5 minutes Battery reconnection is reported within 1 minute power limited Fig 1b pg 5 BAT Stand by battery connections Maxi...

Страница 6: ...Power Limited Outputs N COMMON POWER OUTPUTS P FUSED POWER OUTPUTS 1 2 3 4 5 6 7 8 D1 INPUT R1 LED DC Output to devices 1P 8P Power Outputs 1N 8N Common Outputs From Power Supply Board Factory Install...

Страница 7: ...294 Applications Note 12V batteries are required for UL603 UL1481 and Canadian installations CAUTION Power supply board is factory set for 24VDC Use two 2 12VDC stand by batteries Keep power limited w...

Страница 8: ...employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods For Canadian ins...

Страница 9: ...minimum 0 25 spacing 12AH Rechargeable batteries are the largest batteries that can fit in this enclosure A UL listed external battery enclosure must be used if using 40AH or 65AH batteries Optional...

Страница 10: ...employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods For Canadian inst...

Страница 11: ...x 82 6mm 1 40 35 6mm 1 40 35 6mm 1 40 35 6mm 4 85 123 2mm 4 85 123 2mm 3 25 82 6mm 0 75 19 1mm 0 75 19 1mm 11 0 279 4mm 12 5 317 5mm 1 20 30 5mm 1 20 30 5mm 0 9375 23 8mm 0 9375 23 8mm 5 10 129 5mm 1...

Страница 12: ...25 28 6mm 1 5 38 1mm 1 5 38 1mm 5 0 127 0mm 5 0 127 0mm 4 5 114 3mm 4 5 114 3mm 1 25 31 8mm 1 25 31 8mm 0 79 20 1mm 0 91 23 1mm 0 91 23 1mm 15 5 393 7mm 1 1 27 9mm 1 1 27 9mm 1 1 27 9mm 12 23 310 6mm...

Страница 13: ...ectric w 135o Thermal Supervisory Relay 15 45 2312 24TB Photoelectric 0 12 50 2412 12 volt Photoelectric 0 12 77 2424 Photoelectric 0 10 41 2451 Photoelectric 0 10 39 2451TH with B402B Base Photoelect...

Страница 14: ...emote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output...

Страница 15: ...ltronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warra...

Страница 16: ...5AH 6A 10A 1 5A 10A Over 4 Hours 10A Battery Backup Built in charger for sealed lead acid or gel type batteries Maximum charge current 1 0A Automatic switch over to stand by battery when AC fails Tran...