17.10 To view or edit the communications setup, select “COMMUNICATIONS” from the main menu
and press ENTER.
EDIT SAFETY SHUTDOWN
HOURMETER FUNCTIONS
6
COMMUNICATIONS
NEXT MENU
ENTER
press to
edit
commun-
ications
COMMUNICATIONS
NODE
6
1
PORT 1 ASCII
PORT 3 MODBUS RTU
Use the NEXT key to select node, port 1 or port 3; then use the UP or DOWN arrow keys to
change the node number from 1 to 99 and port 1 and port 3 from ASCII to MODBUS
communications. Press the ENTER key to save the selection.
17.11 To view or edit the time and date, select “NEXT MENU” from the main menu. Then select
“EDIT TIME AND DATE”.
→
EDIT TIME AND DATE
VIEW FIRMWARE REV.
PREVIOUS MENU
from
ENTER
press
The time and date will be displayed with the selection arrow pointing to the time. The hours,
and minutes can be edited separately, AM and PM follow the minutes. With the selection
arrow pointing to the hours, use the
↑
UNITS or
↓
UNITS keys to increase or decrease the
hours. Press ENTER to save the new hour setting; the selection arrow will point to the
minutes. Use the same procedure to edit the minutes. Use the NEXT key to move through
the time and date screen without making a permanent change in memory.
TIME:
→
11:30 AM
DATE: 03-25-2001