Page - 14 -
CLARKE TECHNOLOGY Operator's Manual - Ultra Speed Burnisher
230 VOLT MACHINES
Instructions for connection to the power
supply and the electrical ground.
This product must be grounded. If the installation
should breakdown, grounding provides a path of low
resistance for electric current to reduce the risk of
electrical shock. This product is equipped with a cord
having an equipment-grounding conductor and ground-
ing plug. The plug must be inserted into an appropriate
outlet that is properly installed and grounded in accor-
dance with all local codes and ordinances.
WARNING:
Improper connection of the
equipment-grounding conductor can re
sult in a risk of electric shock. Check with
a qualified electrician or service person if
you are in doubt as to whether the outlet is
properly grounded.
This product is for use on a nominal 230 volt circuit. The
plug on this product must be replaced with a three
contact grounding style plug, having a configuration
appropriate for connection to the local power supply.
The new plug must be installed by a qualified electri-
cian.
WARNING: To prevent possible electric
shock, protect the machine from rain.
Keep the machine in a dry building.
WARNING: To prevent possible electric
shock, always use a 3-wire electrical
system connected to the electrical ground.
For maximum protection against electri
cal shock, use a circuit that is protected by
a ground fault circuit interrupter. Consult
your electrical contractor.
WARNING: Do not cut, remove or break
the ground pin. If the plug does not fit
your outlet, consult your electrical
contractor.
WARNING: Have worn, cut or damaged
cords replaced by an authorized service
person.
EXTENSION CORDS
Use only an approved extension cord with three con-
ductors, a plug with three terminals, and a connector
body with three holes. The machine has a power cord
with wire size 14 AWG.
WARNING: If you use an extension
cord, use an extension cord with
minimum wire size 12 AWG. Do not use
an extension cord longer than 50 feet.
Do not join two extension cords.