I
NSTALLATION
Converge®
▪
Operator’s Manual
▪
MN-47238
▪
Rev 1
▪
8/22
33
How to Install the Oven
(50 Hz Models Without Cord or
Plug)
Before you begin
Make sure
you have:
▪
An appropriate lifting device, and enough personnel, to safely move and position
the weight of the oven.
□
CMC-H2H: 304 lb (138 kg)
□
CMC-H3H: 394 lb (179 kg)
Requirements
▪
The oven must be installed on a level surface.
▪
The oven must not be installed in any area where it may be affected by steam,
grease, dripping water, high temperature, or any other severely adverse
conditions.
▪
The oven is not intended for built-in installation.
▪
For 3-phase applications, an RCD Type B protection device must be installed. The
device must accommodate a leakage current that may exceed 10 mA.
▪
If a power cord is used for the connection of the product, an oil resistant cord like
H05RN or H07RN or equivalent must be used.
Voltages
Continued on next page
V
Ph
Hz
A
Breaker*
kW
CMC-H2H
380
415
3
3
50
50
11
12
30
30
7.5
8.9
CMC-H3H
380
415
3
3
50
50
17
19
50
50
11.3
13.4
*Electrical connections must meet all applicable federal, state, and local codes.
Содержание Converge CMC-H2H
Страница 4: ...FOREWORD Converge Operator s Manual MN 47238 Rev 1 8 22 4 This page is intentionally left blank ...
Страница 12: ...SAFETY Converge Operator s Manual MN 47238 Rev 1 8 22 12 This page is intentionally left blank ...
Страница 20: ...LABELS Converge Operator s Manual MN 47238 Rev 1 8 22 20 This page is intentionally left blank ...
Страница 44: ...INSTALLATION Converge Operator s Manual MN 47238 Rev 1 8 22 44 This page is intentionally left blank ...
Страница 98: ...TROUBLESHOOTING Converge Operator s Manual MN 47238 Rev 1 8 22 98 This page is intentionally left blank ...
Страница 101: ...DECLARATION OF CONFORMITY Converge Operator s Manual MN 47238 Rev 1 8 22 101 D ECLARATION OF C ONFORMITY ...
Страница 102: ...DECLARATION OF CONFORMITY Converge Operator s Manual MN 47238 Rev 1 8 22 102 ...
Страница 103: ......